background image

INSTALLING THE COOKER INTO THE SISTEM FOR WATER HEATING

 

-

  For  water  supply  and  drainage  in  condominial  (central)  heating  system  are  provided 

connections to the boiler 1 ".

 

-

 The stove can be installed on an indoor or outdoor central heating system.

 

 

Installation on closed central heating system

 

 

One of the possible installation processes is shown in Figure 8.

 

 

-

The safety valve must be placed close to the boiler and must be set to a maximum pressure 

of 3 bar (boiler is tested to 4 bar). The connecting line of the safety valve must be as short as 
possible and must not have the possibility of closing. In this connecting line also there must 
not be any single valve or any other fitting.

 

-

Closed  expansion  vessel  is  placed  close  to  the  boiler  and  has  a  short  security  line.  The 

volume of the expansion vessel is calculated by the folloving formula:

 

V = 0,07xVwater,  (l), where Vwater is volume of the water in entire system. 

 

-

The installation of the safety fuse of the boiler it's necessary. We highly recommend a Caleffi 

544 thermal fuse. 

-

 The instalation of vent valve (authomatic preferably) 

-

 Before starting the stove, it’s necessary to vent the system

 

Summary of Contents for NIKA- HYDRO

Page 1: ...NIKA HYDRO Fireplace stove on solid fuel Owners s manual INSTALATION ADJUSTMENT AND OPERATING INSTRUCTION EN 13240...

Page 2: ...our stove Keep it handy and refer to it as needed You will find in it information that will be useful now and in the years to come Make sure that when installing the stowe all security standards have...

Page 3: ...Bookmark not defined INSTALLING THE STOVE INTO THE SYSTEM FOR WATER HEATING Error Bookmark not defined Installaion on closed central heating system Error Bookmark not defined Installaion on opened cen...

Page 4: ...g it Do not allow children to handle and play near the stove Only spare partes reccomended and allowed by the manufacturer should be installed on the stove You must not make any changes on the stove W...

Page 5: ...The upper plate of the fireplace is made of steal figure 1 position 1 Firebox doors figure 1 position 4 are made of cast iron with fireproof glass Connection for smoke drain figure 1 position 2 is mad...

Page 6: ...entral on upper plate Consuption by nominal power kg h 2 65 Emission temperature C 241 Air regulation Primary Automatski Rathgeber Secundary Manual Required amount of water in the boiler l 12 5 Requir...

Page 7: ...eeply into the chimney that would reduce the cross sectional area and thus undermined draft in the chimney Do not use reducers which reduce the cross section of pipe smoke The stove requires insertion...

Page 8: ...raft in the chimney Figure 3a check the chimney functioning The chimney should be located inside the building and if it s located on the external walls of the building it s highly recommended insulati...

Page 9: ...ut 2 Excessive slope 3 A sudden change of direction of the channel 4 Stove or some other evice is connected to the same flue channel 5 Bulges in the channel 6 Cracks 7 Alien body or acumulated grime 8...

Page 10: ...must wait until entire amount of a fuel lightens up and only then reduce draft on half when adding fuel open the firebox door for just few degrees wait for 4 5 seconds and then slowly open them wide D...

Page 11: ...inserted only after the previous volume burn Do not allow that ashes and unburned accumulate on the grid and to ta pit that way Clean the grid Open the door slowly and carefully allowing that way equa...

Page 12: ...clean the rost grid in order to provide the fresh air supply Regularly clean the ash tray making sure that there is always enough place for ashes The stove is designed to operate in periodic mode To...

Page 13: ...ulation of secondary air Secondary air regulator put into position open Figure 7a during firing and keep in this position until establishing the stable operation of the stove after loading some larger...

Page 14: ...ed to 4 bar The connecting line of the safety valve must be as short as possible and must not have the possibility of closing In this connecting line also there must not be any single valve or any oth...

Page 15: ...Figure 8 closed central heating system...

Page 16: ...ional service in charge that guarantees the correct operation of the entire heating system In case of bad design of the system and possible shortcomings while installing it by the entity that did the...

Page 17: ...Figure 9 Open central heating system...

Page 18: ...eaning use protective gloves Clean the bottom of the ovenfrom accumulated ash and pick up small unburned pieces of the grid clean the ashtray and ash accumulated in the interior of the fireplace Clean...

Page 19: ...ke reenters into a room Closed regulator of air supply Insufficient draft Remainings of ashes on a grid Open the regulator of air supplyand provide a supply of a primary air Read carefully the instruc...

Page 20: ...the manufacturer s service only If unauthorized persons carry out any servicing or repairs and alterations to the stove the owner loses the right to the manufacturer s warranty Supply of spare parts h...

Page 21: ...is forbiden burning an inorganic and organic materials plastics plywood textile oiled wood etc because the combustion releases carcinogenic materials and other toxics FIREPLACE SOLID FUEL STOVE NIKA H...

Page 22: ...cleaner structure 12 Authomatic regulation of a primar air 13 Pin 14 The base structure 15 Grid 16 Lever 17 Ashtray 18 Firebox door 19 Firebox door handle 20 Firebox door glass 21 Secondary air handl...

Page 23: ...Dimensions of the stove...

Page 24: ...the seller Detail protocol must be released by the offitial seller of TIM SISTE product This warranty will be accepted only if Product has been used according to this manual Product is not fisicaly d...

Page 25: ...___________________________ __________________________________________________________________________ __________________________________________________________________________ ______________________...

Page 26: ......

Page 27: ......

Page 28: ...TIM SISTEM d o o Prva industrijska 9 22330 Nova Pazova Serbia tel 381 22 328 076 e mail office timsistem rs www timsistem rs...

Reviews: