DO NOT pour water into the cooker or chimney
• A fire in the chimney can be extinct only with dry powder
• Water can extinguish only a surrounding material
• Do not cool the surrounding walls with water
Important notice:
If the fire, for some reason becomes dangerously strong, please take the following
measures: close the air supply, which provide air for combustion. If necessary, throw in the
firebox sand or fireproof blanket. It would be good having fire extinguisher for that purpose.
Before the second charging, clean the rost grid in order to provide the fresh air supply.
Regularly clean the ash tray making sure that there is always enough place for ashes.
The stove is designed to operate in periodic mode. To maintain the required nominal power,
combustion chamber is periodically filled with prestabled amount of fuel.
Furnace is not designed to operate in continuous mode of heating or in accumulating
temperature mode.
Authomatic regulation of stove operation
Combustion rate, and thus the amount of heat generated by stove, depends on the amount
of primary combustion air delivered to the space below the roast grid. The regulation of
primary air is accomplished automatically by draft regulator Rathgeber (Figure 5).