- Parameter N-9-6-17 (1500 RPM*) Speed of exhaust gasses fan in period between detecting stabile 
fire and working mode   

*  RPM stands for :  Round Per Minute   

  
In this phase it is important to follow up the way of burning in the burning pot. In case of high  
speed or low speed of exhaust fan, parameters should be tuned and corrected (depending on air flow 
and draft of chimney). Check the look of flame, if the flame is “dancing” and wood pellet is 
“bouncing” in the burning pot, fan speed should be reduced.   
 

 

“Dancing fire” and “bouncing pellet”       /        Stabile and established fire 

 
 

WORKING MODE  

  
After entering working mode, Installer is obliged to monitor and to follow up the way stove is 
working in Mode 5 and Mode 1 (maximum and minimum).   
Stove is set to maximal power 14 kw (4 kW given to room, i 10 kW given to water), until in MODE 
1, WORK MODULATION (on minimum) Power is set to 6kW (2,2 kW given to room and 3,5 kW 
given to water). Thermal output is influenced by quality of pellet.  
  
Having in mind that one working cycle of stove is determined with parameter N-9-6-3 (15 minutes) 
and that cleaning is determined with parameter  N-9-6-12 (30 second).   

 
WARNING: 
Installer is obliged to follow up at least 3 working cycles including cleaning of burning pot 
(both minimal and maximal values).   

 
 

REMARK:   

Parameters which are influencing cleaning of burning pot are:   
- N-9-6-3 Time duration of burning pot cleaning. Every 15 minutes, exhaust gasses fan blowing is 
increasing in order to clean burning pot.  
- N-9-6-12 Time interval of burning pot cleaning (45 seconds)  
- N-9-6-29 Fan speed during cleaning of burning pot (2100 RPM)  
- N-9-6-30 Loading pellet during cleaning of burning pot (0,5 second)  
  
In this phase it is important to follow up the way of burning fuel in the burning pot in order to  
prevent high speed of exhaust fan which result with “bouncing pellet”   

Summary of Contents for Aquas 15

Page 1: ...of using external thermostat INSTALLERS MANUAL INSTRUCTION FOR INITIAL STARTING OF INDOOR PELLET STOVES HYDRO MODELS Rittium 14 Rittiul 20 Aquas 15 Aquas 20 Aquas 15 Aquas 22 for hydro stoves Separate...

Page 2: ...STARTING FIRE PROCESS________________________5 ESTABLISHING FLAME FLAME LIGHT ______________________________5 WORKING MODE ________________________________________________6 RECOMENDATIONS RELATED CHIM...

Page 3: ...o connect it to stove Is stove connected to a heating system in proper way What is the quality and condition of residential heating system Before kindling the stove it is preferable to inform stove us...

Page 4: ...ameters In upper left corner of the screen you will find symbol 00 Press the button 1 to get to symbol A9 1 2 3 98 99 A1 A2 A9 A9 is PASSWORD to enter PARAMETER SETTINGS Push the button SET 3 to enter...

Page 5: ...e temperature of igniter will be influenced by high speed of blowing fan After initial pellet loading Auger will make a brake of 100 seconds Par N 9 4 04 in order to wait for establishing of fire Afte...

Page 6: ...E 1 WORK MODULATION on minimum Power is set to 6kW 2 2 kW given to room and 3 5 kW given to water Thermal output is influenced by quality of pellet Having in mind that one working cycle of stove is de...

Page 7: ...probe and in time Sound alert NO FIRE is appearing This moment is determined with parameter N 9 6 13 50 C Solution to this problem If you decide to leave 15 minutes working cycle that interval of bur...

Page 8: ...ging other parameters If you decide to leave 15 minutes working cycle that interval of burning pot cleaning should be increased from 30 to 35 seconds If you decide to leave interval of burning pot cle...

Page 9: ...ses for connecting the stove to the chimney are not allowed Installation of flue pipes from the furnace to the chimney should be done in such a way that they are hermetically The stove must be install...

Page 10: ...cleaning mode All parameters above parameters had the same values no matter that stove is working on minimum power or maximum power and sometimes it s difficult to adjust cleaning for both max and min...

Page 11: ...r OFF directly from display N 9 6 36 value 02 Stove goes into STAND BY mode following external room thermostat in that case ambient probe on stove back is automatically disabled and temperature probe...

Page 12: ...12...

Page 13: ...13...

Reviews: