10
NEW FIRMWARE:
- Serbian Language
- Separate cleaning parameters for regime's P1/P2 and P3/P4/P5
- 3 different option for entering into STAND BY (by ambient temp., by water temper. or by external
thermostat temperature)
- new way of using external thermostat
Main improvements is:
In old firmware cleaning process of burning pot was defined by 4 parameters:
- speed of exhaust fan through cleaning process (was the same value for all 5 regimes modes)
- duration between two cleaning process (in minutes)
- duration of cleaning period (in seconds)
- auger work in cleaning mode
All parameters above parameters had the same values, no matter that stove is working on
minimum power or maximum power (and sometimes it's difficult to adjust cleaning for both max.
and min. power settings)
Changes are reflected in the way that cleaning mode is separated on 2 parts:
- cleaning mode with their parameters for regimes P1 and P2,
Parameters
speed of exhaust fan
N-9-4-12
duration between two cleaning process
N-9-4-13
duration of cleaning period
N-9-4-14
auger work in cleaning mode
N-9-4-15
- cleaning mode with their parameters for regimes P3, P4 and P5
Parameters
speed of exhaust fan
N-9-6-03
duration between two cleaning process
N-9-6-12
duration of cleaning period
N-9-6-20
auger work in cleaning mode
N-9-6-30