background image

10 

 

 

NEW FIRMWARE: 

 
 
- Serbian Language  
- Separate cleaning  parameters for regime's P1/P2  and P3/P4/P5 
- 3 different option for entering into STAND BY (by ambient temp., by water temper. or by external 
thermostat temperature) 
- new way of using external thermostat 
 
 
Main improvements is: 
 
In old firmware cleaning process of burning  pot was defined by 4 parameters:  
 
- speed of exhaust fan through cleaning process (was the same value for all 5 regimes modes) 
- duration between two cleaning process (in minutes) 
- duration of cleaning period (in seconds) 
- auger work in cleaning mode 
 

All parameters above parameters had the same values, no matter that stove is working on 

minimum power or maximum power (and sometimes it's difficult to adjust cleaning  for both max. 
and min. power settings) 
 
 

Changes are reflected in the way that  cleaning mode is separated on 2  parts: 
 
- cleaning mode with their parameters for regimes P1 and P2,   
 

 

Parameters 

speed of exhaust fan 

 

N-9-4-12 

duration between two cleaning process

 

N-9-4-13 

duration of cleaning period

 

N-9-4-14 

auger work in cleaning mode

 

N-9-4-15 

 
 
- cleaning mode with their parameters for regimes P3, P4 and P5 

 
 

Parameters 

speed of exhaust fan 

 

N-9-6-03 

duration between two cleaning process

 

N-9-6-12 

duration of cleaning period

 

N-9-6-20 

auger work in cleaning mode

 

N-9-6-30 

 

 

 

Summary of Contents for Aquas 15

Page 1: ...of using external thermostat INSTALLERS MANUAL INSTRUCTION FOR INITIAL STARTING OF INDOOR PELLET STOVES HYDRO MODELS Rittium 14 Rittiul 20 Aquas 15 Aquas 20 Aquas 15 Aquas 22 for hydro stoves Separate...

Page 2: ...STARTING FIRE PROCESS________________________5 ESTABLISHING FLAME FLAME LIGHT ______________________________5 WORKING MODE ________________________________________________6 RECOMENDATIONS RELATED CHIM...

Page 3: ...o connect it to stove Is stove connected to a heating system in proper way What is the quality and condition of residential heating system Before kindling the stove it is preferable to inform stove us...

Page 4: ...ameters In upper left corner of the screen you will find symbol 00 Press the button 1 to get to symbol A9 1 2 3 98 99 A1 A2 A9 A9 is PASSWORD to enter PARAMETER SETTINGS Push the button SET 3 to enter...

Page 5: ...e temperature of igniter will be influenced by high speed of blowing fan After initial pellet loading Auger will make a brake of 100 seconds Par N 9 4 04 in order to wait for establishing of fire Afte...

Page 6: ...E 1 WORK MODULATION on minimum Power is set to 6kW 2 2 kW given to room and 3 5 kW given to water Thermal output is influenced by quality of pellet Having in mind that one working cycle of stove is de...

Page 7: ...probe and in time Sound alert NO FIRE is appearing This moment is determined with parameter N 9 6 13 50 C Solution to this problem If you decide to leave 15 minutes working cycle that interval of bur...

Page 8: ...ging other parameters If you decide to leave 15 minutes working cycle that interval of burning pot cleaning should be increased from 30 to 35 seconds If you decide to leave interval of burning pot cle...

Page 9: ...ses for connecting the stove to the chimney are not allowed Installation of flue pipes from the furnace to the chimney should be done in such a way that they are hermetically The stove must be install...

Page 10: ...cleaning mode All parameters above parameters had the same values no matter that stove is working on minimum power or maximum power and sometimes it s difficult to adjust cleaning for both max and min...

Page 11: ...r OFF directly from display N 9 6 36 value 02 Stove goes into STAND BY mode following external room thermostat in that case ambient probe on stove back is automatically disabled and temperature probe...

Page 12: ...12...

Page 13: ...13...

Reviews: