TECHNISONIC INDUSTRIES LIMITED
www.til.ca
TDFM-7000 Installation & Operating Instructions
TiL 05RE375 Rev n/c Issue 13
2-5
The function keys along with the rest of the keypad, revert to normal number keys during
transmit and when NUM LOCK is selected by pressing the rotary knob.
The F1 – F4 keys can be programmed as quick channel keys as mentioned in 2.7.
Depending on the setting in the configuration menu, the keys can be permanently set to
channels or used for other functions (normal). When the F1 –F4 keys are in the normal
mode they can still be used for quick channels if the FUNC key is pressed first.
2.9
MUP(4) AND MDN(7) KEYS (Memory Up and Down Keys)
These keys provide the same function as the rotary knob does when it is set to CHAN. This
equates to the 16 position rotary knob on the portable. When one of these keys is pressed,
the function of the rotary knob is automatically set to CHAN.
2.10 UP(5) AND DN(8) KEYS
The keys provide the same function as the left and right arrow keys on the portable. The UP
key equates to the right arrow key. These keys are used for a variety of functions but in the
normal mode they are used to scroll through the soft key menus.
2.11 BRT(6) AND DIM(9) KEYS
Use these keys to dim or brighten the display. The radio powers up at full brightness for
normal use but can be dimmed for night operations.
2.12 ESW(0) KEY (Ergo Switch Key)
The ESW key provides the function of the concentric or ‘ergo’ switch on the portable. The
switch has two conditions which are represented by ‘O’ and ‘
∅
’. Pressing the ESW key
toggles the condition back and forth. The condition is displayed at the right hand side of the
display line, second character from the right. The ergo switch condition is saved when the
unit is turned off. There are separate conditions for each band installed. The ESW key can
be programmed with the CPS™ to a variety of functions such as low power, scan and
secure or encrypted mode.
2.13 TSW (*) KEY (Toggle Switch Key)
The TSW key provides the function of the toggle switch on the portable. The switch has
three conditions which are represented by ‘A’, ‘B’ and ‘C’. Pressing the TSW key toggles
the condition A,B,C,A,B, etc. The condition is displayed at the right hand side of the display
line, last character on the right. The toggle switch condition is saved when the unit is turned
off. There are separate conditions for each band installed. The TSW key can be programmed
with the CPS™ to a variety of functions such as low power, scan, zone select, or pl disabled
mode.
2.14 DISPLAY
The transceiver has a 5-line, 120-character LED display. The top 4 lines display the zone
name, channel name, condition symbols (scan, direct, call, secure, monitor, etc) and switch
settings for each band. An LED on the left side of each band indicates a receive condition
while an LED on the right side of each line indicates transmit. A solid arrow on the first
character indicates which band is selected. The fifth line displays the menu items associated
with the band selected and the mode the knob is in.