![Tiger CB-0050 Instruction Manual Download Page 10](http://html.mh-extra.com/html/tiger/cb-0050/cb-0050_instruction-manual_1114828010.webp)
www. gerlif ng.com
Unit 1,
'ƌĞĞŶƐĮ
eld Industrial Estate,
Willowburn Avenue,
ALNWICK, NE66 2DG
Email: info@ gerli ing.com
www.tigerlifting.com
Page 9
of 18
The hook opening will elongate with overloads and incorrect hooking. When the hook measurements have changed beyond
the permissible discard limits shown in the t able in Chapter 7 Technical Data /Hooks, it is dangerously deformed and must be
replaced immediately.
Dye penetrant, magnetic particle inspections (MPI) or other suitable crack detecting inspections should be performed on
hooks at least once a year, if external conditions indicate there has been unusual usage.
TR7 products are fitted with the patent pending Tiger “EZ check” 3 point marking system. With this system a quick check that
the A and B measurements are the same ( as shown in the diagram below ) will indicate if the hooks have stretched
If A
ɩ
B the hook is fine; If A>B the hook needs to be replaced:
5.
Maintenance
Never perform maintenance on the hoist while it is supporting a load.
Before performing maintenance attach a notice/tag to the block to indicate that it must not be used while maintenance
is in progress.
Servicing and repairs should only be carried out by qualified, competent, and responsible people.
After performing any maintenance to the hoist, always perform a functional test before returning to service. After the
replacement of components, a subsequent inspection by a competent person is obligatory!
Repair work may only be carried out by a specialist workshop that uses original Tiger spare parts.
Before handling lubricants, read the associated product health and safety data information sheet obtained from the
lubricant supplier.
! WARNING
28/12/2017
www. gerlif ng.com
Unit 1,
'ƌĞĞŶƐĮ
eld Industrial Estate,
Willowburn Avenue,
ALNWICK, NE66 2DG
Email: info@ gerli ing.com
www.tigerlifting.com
Page 10 of 18
Store the unit in a clean and dry place.
Protect the unit including all accessories against contamination, humidity and damage by means of a suitable cover.
Protect against corrosion.
Wipe off all dirt and water.
A light oil film should be applied to the chains , hook pins and hook latch pins.
Since the brake disks may freeze at temperature below 0°C, the unit s hould be stored with closed brake. Turn the
hand chain wheel clockwise to this effect and hold the load fall at the same time.
If the unit is to be used again after i t has been taken out of service, it must first be inspected again by a competent
person.
Disposal
When the product comes to the end of its lifecycle, after taking the unit out of service, recycle or dispose of the parts of the
unit respecting local and national environmental regulations.
6.
Manufacturer Testing and Verification
This product was manufactured under our single -unit control of quality and was passed with strict inspection in accordance
with our inspection standards.
Capacity (tonne)
WLL (kg)
Test Load (kg)
0.5
500
750
1
1000
1500
1.5
1500
2250
2
2000
3000
3
3000
4500
5
5000
7500
Declaration of Conformity
Products are tested in line with the requirements within applicable sections of the European standard BS EN
13157: 2004+A1:2009, the Australian standard AS1418.2, the American standard ANSI/ASME B30.16, and the South African
standard SANS 1594 . All items comply with the essential health and safety requirements of the Machinery Directive
2006/42/EC. Tiger chain blocks are third party verified by SGS Certificate Number MDC 1302.
28/12/2017
ͻ
ͻ
ͻ
ͻ
ͻ
ͻ
ͻ