Function
Indicator Factory Default Parameter Set Range
Instruction
Time of Day
Random
00:00
~
23:59
Set the current time of day while the “:” flashes.
Control Mode
A-01
A-01
A-01
Meter Delayed. Regeneration occurs at the set regeneration time
once the gallons used reaches zero (0).
A-02
Meter Immediate. Regeneration occurs immediately once the
gallons used reaches zero (0).
A-03
Not Applicable for
U.S. Customers
Meter Delayed - set resin volume, feed water hardness, and
regeneration factor; the valve will calculate the system capacity.
Regeneration mode same as A-01.
A-04
Not Applicable for
U.S. Customers
Meter Immediate - set resin volume, feed water hardness, and
regeneration factor; the valve will calculate the system capacity.
Regeneration mode same as A-02.
Unit Mode
HU-02
HU-02
01, 02, 03
01-m
3
; 02-gal; 03-L
Regeneration Time
02:00
02:00
00:00
~
23:59
Regeneration time. “:” light on
Interval Backwash
Times
F-00
00
0
~
20
Interval backwash times. Number listed after F indicates
number of additional backwashes between services.
Resin Volume
20L
20L
5
-
500L
Resin volume in pressure tank (L)
Only for A-03 and A-04 mode.
Not applicable for U.S. installations.
Feed Water
Hardness
Yd1.2
1.2
0.1
-
9.9
Feed water hardness (mmo1/L)
Only for A-03 and A-04 mode.
Not applicable for U.S. installations.
Exchange Factor
AL.65
0.65
0.30
-
0.99
Relate to the raw water hardness. When hardness is higher, the
factor is smaller.
Only for A-03 and A-04 mode. Not applicable
for U.S. installations.
Water Treatment
Capacity
2500
0-10,000
To figure capacity, take the total resin volume multiplied by .75.
Divide by grains hardness of water supply. Example: 1 Cu/Ft =
32,000 x .75 at 15 grains hardness. (32,000 x .75) ÷ 15= 1600 gal.
Enter that value here.
Backwash Time
10 min.
0
~
99
∶
59
Backwash time.
Brine & Slow Rinse
Time
60 min.
0
~
99
∶
59
Brine & Slow Rinse time.
Brine Refill Time
10 min.
0
~
99
∶
59
Refill time is calculated based on total resin volume. Note: 1 gal
water dissolves 3lbs of salt. Refer to bottom of page 12 for refill
time.
Fast Rinse Time
10 min.
0
~
99
∶
59
Maximum Interval
Regeneration Days
H-30
30
0
~
40
Output Control
Mode
b-01
01
01 or 02
MASTER PROGRAMMING
1
6
Fast Rinse time.
Forced regeneration every 30 days if no water has been used.
Time Clock Valve: to operate as a time clock valve, set the
number of days before desired regenerat ion.
end of regeneration.
b-
during In Service.
b-01: Signal turns on at start of regeneration and shuts off at
02: Signal available in intervals during regeneration cycles and