496
Sensors (Probes)
© Tibbo Technology Inc.
IO Ninja toolbar
·
Click
New Session
, then choose
Serial
.
·
Click
New Layer
and add the
XModem
layer.
·
Click
Settings
and make sure that:
o
Correct
Port
is selected;
o
The
Baud rate
is
38400
;
o
The number of
Data Bits
is set to
8
;
o
The number of
Stop Bits
is set to
1
; and
o
Parity
is set to
None
.
o
The
flow control
is set to
None
.
·
Click
Open
.
·
Click
Transmit File With XModem
, select the firmware file to send, and click
Open
.
·
Press and hold the
on the Bus Probe. Each Bus Probe comes with a
metal pin that makes pushing and holding down the MD button easier.
·
Apply power to the Bus Probe. The upload should start. You may release the MD
button at this point.
·
During the upload, the
will be showing the following patterns:
o
— the Probe is receiving and storing the file;
o
— XModem transmission completed;
o
A number of error patterns may also be displayed. Please refer to the
·
After the upload completes, power-cycle the Probe. The newly loaded application
firmware will start executing.