2007.03.07
Flow2 stairlift
Tab 04: Install, adjust and release
www.ThyssenKruppAccessibility.nl
13
Assembly
5. If there is no end cap, fit an end cap on the end of the rail.
6. Turn the handle on the support bracket, shown in the
figure, two ways to check whether the motor runs. You use
this handle for driving on the drive unit
3.3
Driving onto the rail
The drive unit is positioned on the top frame at the driving-on point, it can now be easily driven onto
the rail. Ensure that you are standing in front of the drive unit as shown in Fig. 3-9.
1. Ensure that the transformer plug is not plugged into the wall socket.
2. Position the forks of the loading assembly straight under the drive unit so that they are in line
with the rack while driving onto the rail.
3. Grasp the drive unit by the support bracket and the undercarriage.
Display
Pushbuttons [D] [E] [I]
Mode switch
Laptop connection
Armrest control connection
Support bracket
connection
Fig. 3-5
Service board
Fig. 3-6
ESD precautions
1
Fig. 3-7
Operating handle
1
CAUTION
Take ESD precautions, such as a mat, strap and shoes. Never touch a circuit board
without taking these precautions.
CAUTION
Check the wiring if the motor does not run.