18
DROP MECHANISM LUBRICATION
Periodic lubrication of the drop mechanisms will insure smooth, crisp drops. We recommend that you use 3-IN-ONE oil after about
500 adjustments or once/month, whichever comes first. If the drops have not been lubricated on a regular basis, it is recommend to first
clean the plungers using WD-40. See instructions below.
CERVICAL DROPS
THORACIC & PELVIC DROPS
1. Elevate the headpiece (as shown) and cock the drop mechanism.
2. Apply 3-IN-ONE into the hole of the drop mechanism
housing. Allow a few minutes for the lubricant to penetrate
the mechanism before using the headpiece drops.
1. Cock each drop section and then tip the table onto its side
with the cocking handles. This will expose the lubrication
hole in the drop mechanism housing (located on the opposite
side of the cocking handles).
2. Apply 3-IN-ONE oil into this hole. Allow a few minutes
for the lubricant to penetrate the mechanism before using
the drop.
UPHOLSTERY
Normal day to day soil on the vinyl upholstery can be removed
with neutral soap and warm water followed by a thorough water
rinse. Avoid harsh detergents and powdered abrasives. Areas
coming in contact with hair, body oils or perspiration should be
washed frequently. Remove stains immediately to prevent the
possibility of them becoming permanent. In the event of damage,
pre-sewn replacement upholstery is available from Thuli Tables.
Care & Maintenance
18
If the drops have not been lubricated on a regular basis:
Routine lubrication:
1. First clean the plunger from accumulated dust and debris
by applying WD-40 (as described above) and then drop the
headpiece several times.
2. Apply 3-IN-ONE oil to lubricate the drops (as described
above).
Routine lubrication:
If the drops have not been lubricated on a regular basis:
1. First clean the plungers from accumulated dust and debris by
applying WD-40 (as described above) and then drop the
section several times.
2. Apply 3-IN-ONE oil to lubricate the drops (as described above).
TENSION CONTROL ADJUSTMENT
The set screw on the bottom of the thoracic, pelvic and caudal
drop mechanisms can be adjusted (using an 1/8” allen wrench)
so that the tension control rod has more or less resistance.
See photo above.
Increase resistance: Turn the set screw clockwise. This is
helpful if the tension control rod is “backing out" while using
the drop.
Decrease resistance: Turn the set screw counter-clockwise.
Set Screw