S2R-H80 Single & Dual Cockpit
AIRPLANE FLIGHT MANUAL
AFM H8001 SINGLE & DUAL COCKPIT Revision B
Page 23
FAA APPROVAL DATE: 3/19/2015
l.
Auto Start Enable switch
ON
m.
Fuel Condition Lever
IDLE
n.
Start switch
FORWARD to Start position and
HOLD for three seconds, then
release
m.
OBSERVE:
That the engine accelerates normally
to idle RPM and that the maximum
allowable inter-turbine temperature
starting limit is not exceeded.
n.
Autostart Enable Switch
OFF
o.
Oil Pressure
CHECK within Green operating
range
p.
Oil Temp
CHECK within Green operating
range prior to accelerating engine
q.
Generator Switch
ON
There is a maximum number of three unsuccessful
start attempts allowed. The fuel drain accumulator
must be drained prior to any additional attempts. This
draining procedure is in the aircraft maintenance
manual.
NOTE:
Battery switch must be on for a ground power start. All other
procedures are the same as a battery start.
CAUTION