If an obstruction such as a pole or a funnel is unavoidable, the following guidelines
apply:
The distance to the obstruction should large enough, so that the obstruction only covers
3 degrees. This means that the safe distance is:
Safe distance = 20 * Diameter of obstruction
Example:
Obstruction is a 4" pole. Diameter = 0.1 m. Safe distance is 20 * 0.1 m = 2 m
Max. obstruction angle 3 degrees
Capsat
Figure 3: TT-3001B Option 001 Maritime Antenna mounting near pole or funnel.