Trouble shooting
Fault
Possible Cause
Remedy
Pilot won’t light.
No gas supply.
Ensure gas isolation valve is turned
on, and that bottles are not empty.
Call the service provider.
Pilot goes out when gas control
knob released.
Releasing knob before the
thermocouple has heated.
Pilot flame too small.
- Gas pressure too low.
- Partially blocked pilot injector.
Thermocouple connection to the
gas control is loose or faulty.
Thermocouple faulty.
Electromagnet in the rear of the
gas control unit is faulty.
Hold knob in for at least 20
seconds following ignition of the
pilot.
Clean or replace the pilot injector.
Tighten the thermocouple
connection.
Check that the thermocouple is
producing between 20-30mV.
Inspect and replace if not in good
working order.
Call the service provider.
Main burner will not light.
Incorrect supply pressure.
Faulty gas control.
Call the service provider.
Call the service provider.
NOTE: Vibration shock caused by shaking or pounding baskets on top surface or by slamming door may cause
Hi-Limit Control Switch to open. If this condition persists, additional cushioning may be added to the rubber
grommets supporting this control to absorb these shocks
.