Cleaning and Maintenance

 

 

 

Thor  equipment  is  constructed  with  the  best  quality  materials  and  is  designed  to  provide  durable 

service  when  properly  maintained.  To  expect  the  best  performance,  your  equipment  must  be 

maintained  in  good  condition  and  cleaned  daily.  Naturally,  the  frequency  and  extent  of  cleaning 

depends on the amount and degree of us age. 

 

Following daily and more extensive periodic maintenance procedures  will increase the life of  your 

equipment. Climatic  conditions  (e.g.,  salt  air)  may  result  in  the  need  for  more  thorough  hand  more 

frequent cleaning in order to keep equipment performing at optimal levels. 

 

 
If necessary to move the fryer for cleaning, etc., drain oil first to avoid death or serious injury. 

 

 

If disconnection of the restraint is necessary to move the appliance for cleaning, etc., reconnect it when 

the appliance is moved to it originally installed position. 

 

 

DAILY CLEANING 

 

1. 

Turn thermostat knob to “0” position. 

 

2. 

Place hot-oil safe container under the drain and drain the fryer pot completely. 

 

3. 

Remove the basket support frame (if applicable) and flush out any sediment remaining in the fryer pot 

with a little hot oil. 

 

4. 

Wipe off the basket support frame and the inside of the fryer pot with a clean cloth. 

 

 

!   

CAUTION 

 

 

 

 

 

 

SOME AREAS OF THE FRYPOT MAY BE HOT!

 

 

5. 

Close drain valve and strain the oil back into the fryer pot through several thicknesses of cheese cloth, 

or filter it back using a filter machine. 

 

6. 

Replace the basket support frame (if applicable) 

 

7. 

Add oil or shortening to MIN oil level mark on rear of fryer pot. 

 

8. 

To resume cooking, turn the thermostat on. 

 

WEEKLY CLEANING 

 

1. 

Follow steps 1 through 4 of the Daily Cleaning procedure (see previous section). 

 

2. 

Close drain valve and fill fryer pot with a solution of warm water and boil-out compound 

 

3. 

Relight the fryer and bring the solution to a gentle boil for at least five minutes. 

 

4. 

Turn off main burners and let the solution stand until the gum deposits are softened and the carbon 

spots and burned grease spots can be rubbed off. 

 

5. 

Scrub the fryer pot walls and heat tubes, then drain out fryer pot and rinse it with clean water. 

 

6. 

Refill the fryer pot with clean water and boil again. 

 

7. 

Turn off gas and drain and rinse well until clean. 

 

8. 

Wipe dry with a clean cloth. 

 

9. 

Refill as specified in the “Filling the Fryer “pot” section 

 

Summary of Contents for GL165-N

Page 1: ...vapors or liquids in the vicinity of this or any other appliances Keep the area free and clear of combustible materials WARNING Improper installation adjustment alteration service or maintenance can c...

Page 2: ...s Unpacking Location Clearances Assembly Gas Connection Commissioning Operation 10 Operation Guide Filling the Fryer Pot Shutdown Procedure Relighting Automatic Pilot Valve High Limit Control Cleaning...

Page 3: ...READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED INTHE EVENT THE USER SMELLS GAS ARE TO BE POST...

Page 4: ...t Chain Gas Supply Requirements Natural Gas G20 Propane G31 Butane G30 GL165 N GL166 N GL165 P GL166 P GL165 P GL166 P Single burner Heat Input 8 8 KW 8 8 KW 8 8 KW 8 8 KW 8 8 KW 8 8 KW Heat Total 26...

Page 5: ...Thor Fryer Manual 12082014 Page 5 Dimensions GL165 P GL165 N GL166 P GL166 N...

Page 6: ...e only to be adjusted by an authorized service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from the appliance including all prote...

Page 7: ...250mm 0mm 0mm Assembly NOTE This appliance is assembled before delivery except castors This appliance is fitted with adjustable castors to enable the appliance to be positioned securely and level Thi...

Page 8: ...t the volume of gas necessary for satisfactory performance A combination gas valve and pressure regulator which is provided with each unit is set to maintain a 1 0kPa manifold pressure for natural gas...

Page 9: ...er is level Use along spirit level four ways across the front and rear of the fryer pot and along each edge Commissioning 1 Before leaving the new installation a Check the following functions in accor...

Page 10: ...g procedure and keep the ignition button down longer Adjustment of pilot flame may be necessary 4 When the pilot stays lit turn the knob counter clockwise to the temperature required Do not press down...

Page 11: ...elted Additional solid shortening can then be added until the desired frying depth has been reached 8 Replace the basket support frame over the fryer pot heat tubes Shutdown Procedure Standby Turn the...

Page 12: ...THIS SPACE All burners are lit from constantly burning pilots Turning the valve to the desired flame height is all that is required to put the unit in service Do not permit fans to blow directly at t...

Page 13: ...support frame if applicable and flush out any sediment remaining in the fryer pot with a little hot oil 4 Wipe off the basket support frame and the inside of the fryer pot with a clean cloth CAUTION...

Page 14: ...bove procedure can usually be removed by rubbing the surface with SCOTCH BRITE scouring pads or STAINLESS scouring pads DO NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust an...

Page 15: ...ce dependable advice or other assistance and for genuine factory parts All units are adjusted at the factory In case of problems in operation at initial installation check type of gas and manifold pre...

Page 16: ...ontrol unit is faulty Hold knob in for at least 20 seconds following ignition of the pilot Clean or replace the pilot injector Tighten the thermocouple connection Check that the thermocouple is produc...

Page 17: ...Explosion drawing GL165 P GL165 N GL166 P GL166 N Thor Fryer Manual 01112013 Page 17...

Page 18: ...1068571 1 7 Basket GL165 P GL165 N GL166 P GL166 N 01 10 1061027 2 8 Flue Rear GL165 P GL165 N GL166 P GL166 N 01 15 1066336 01 15 1066411 1 9 Fryer Restraint Chain GL165 P GL166 P GL165 N GL166 N 06...

Page 19: ......

Page 20: ...V1 Rev2 12 14...

Reviews: