Specifications
General
Stainless steel enclosure
All burner has flame safeguard
The valve is the modulating thermostat with on/off function with temperature selecting knob
Cast iron burner
Thermostat with manual reset limit switch
Three/four burner; Three/four combustion tube
Oil Tank size 14” X 14"
Pack Contents
The following is included:
Gas Fryer
Feet
Instruction Manual
Gas Supply Requirements
2
The burner operating pressure is to be measured at the gas control valve outlet test point with
one burner operating at ‘High’ setting. The operating pressure is ex-factory set, through the
appliance regulator and not to be adjusted.
Minimum input Heat of burner:
21MJ for LPG AND NAT
Natural Gas
Propane
GH110-N
GH111-N
GH110-P
GH111-P
Single burner Heat
Input
32.5 MJ
32.5 MJ
32.5 MJ
32.5 MJ
Heat Total
65 MJ
97.5 MJ
65 MJ
97.5 MJ
Burner Operating
1.0 kPa
2.75 kPa
Supply Pressure
1.0 kPa
2.75 kPa
Gas Connection
¾” BSP
¾” BSP