background image

15 

 

Spare Parts List 

NO. 

DESCRIPTION 

MODEL 

CODE 

QTY 

Dial 

GE756-P 

GE756-N 

06.05.1471455 

Safety Valve 

GE756-P 

GE756-N 

01.20.1068524 

L Connector For Orifice 

GE756-P 

GE756-N 

01.18.1067404 

Main Pipe Assy.- Front 

GE756-P 

GE756-N 

01.24.1070902 

Orifice 

GE756-P 

01.20.1068652 

GE756-N 

01.20.1068637 

Air Shutter 

GE756-P 

GE756-N 

01.02.1005356 

Burner 

GE756-P 

GE756-N 

01.03.1015066 

Trivet 

GE756-P 

GE756-N 

01.11.1062047 

Flue Assy. 

GE756-P 

GE756-N 

06.05.1472409 

10 

L Connector For Manifold 

GE756-P 

GE756-N 

01.02.1005351 

11 

Regulator 

GE756-P 

GE756-N 

01.22.1069526 

   12 

Flame Device System– Rear  

(No include injector) 

GE756-P 

GE756-N 

01.22.1069540 

ODS Injector-0.20 

GE756-P 

01.20.1068546 

ODS Injector-0.40 

GE756-N 

01.20.1068547 

13 

Pilot Pipe Assy.- Rear 

GE756-P 

GE756-N 

01.24.1070904 

14 

Flame Device System– Front  

(No include injector) 

GE756-P 

GE756-N 

01.22.1069539 

ODS Injector-0.20 

GE756-P 

01.20.1068546 

ODS Injector-0.40 

GE756-N 

01.20.1068547 

15 

Pilot Pipe Assy.- Front 

GE756-P 

GE756-N 

01.24.1070903 

16 

Foot 

GE756-P 

GE756-N 

01.02.1005187 

17 

Tray 

GE756-P 

GE756-N 

01.05.1029822 

18 

Main Pipe Assy.- Rear 

GE756-P 

GE756-N 

01.24.1070901 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for GE756-N

Page 1: ...mmable vapors or liquids in the vicinity of this or any other appliances Keep the area free and clear of combustible WARNING Improper installation adjustment alteration service or maintenance can caus...

Page 2: ...ion Requirements Unpacking Location Clearances Assembly Gas Connection Operation 7 Operation Guide Description of Controls Open Burners Cleaning and Maintenance 10 General After Each Use Daily Cleanin...

Page 3: ...PERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCA...

Page 4: ...Input 32 5 MJ 32 5 MJ 32 5 MJ 32 5 MJ Heat Total 65 MJ 195 MJ 65 MJ 195 MJ Burner Operating 1 0kPa 1 0kPa 2 75kPa 2 75kPa Supply Pressure 1 0kPa 1 0kPa 2 75kPa 2 75kPa Gas Connection BSP BSP BSP BSP...

Page 5: ...3 Dimensions GE756 P GE756 N GE757 P GE757 N...

Page 6: ...adjusted by an authorized service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from the appliance including all protective plastic...

Page 7: ...being installed for The gas conversion procedure is detailed in this manual b Supply Pressure required for this appliance is shown in the Gas supply requirements section of this manual Check the gas s...

Page 8: ...e Operation section of this manual Light the Pilot Burner Light the Main Burner Turning Off the Main Burner Pilot b Ensure that the operator has been instructed in the areas of correct lighting operat...

Page 9: ...d by the manufacturer should not be adjusted by the user operator 1 The Gas Hot Plates have been designed to provide simplicity of operation and 100 safety protection 2 Improper operation is therefore...

Page 10: ...zo igniter provided optional 3 Release the gas control knob after approximately 10 20 seconds after lighting the pilot burner 4 The pilot burner should stay alight if not repeat Steps b to c above 5 F...

Page 11: ...reate air cross currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system Otherwise a su...

Page 12: ...warm so that the grease is in a liquid state Empty any grease from the trays and wash thoroughly in the same manner as any cooking utensil 2 Remove the burner the trivets and thoroughly clean the spla...

Page 13: ...he gas control knobs are a push fit onto the gas control valve spindles and can be removed to allow cleaning of the front of the control panel b Baked on deposits or dis colouration may require a good...

Page 14: ...ly Ensure gas isolation valve is turned on and that bottles are not empty Call the service provider Pilot goes out when gas control knob released Releasing knob before the thermocouple has heated Pilo...

Page 15: ...ntact your nearest authorized service branch When ordering replacement parts please quote the part number and the description listing below If the part required is not listed below request the part by...

Page 16: ...14 Explosion Drawing GE756 P GE756 N...

Page 17: ...L Connector For Manifold GE756 P GE756 N 01 02 1005351 1 11 Regulator GE756 P GE756 N 01 22 1069526 1 12 Flame Device System Rear No include injector GE756 P GE756 N 01 22 1069540 1 ODS Injector 0 20...

Page 18: ...16 Explosion Drawing GE757 P GE757 N...

Page 19: ...L Connector For Manifold GE757 P GE757 N 01 02 1005351 1 11 Regulator GE757 P GE757 N 01 22 1069526 1 12 Flame Device System Rear No include injector GE757 P GE757 N 01 22 1069540 3 ODS Injector 0 20...

Page 20: ...18 Please keep this manual in a safe place for future use 15 Badgally Road Campbelltown NSW 2560 V1 Rev0 05 15...

Reviews: