Page 5
Graphic 1.1.2. Legend for the lower ORBIS area
14. Gearmotor.
15. Turning- servo.
16. Micro switch for safety function: Important to prevent motor starting inside the fuselage.
The micro switch will be activated only when the ORBIS is completely extracted and the tilt-servo /
prop mechanism is in flight position.
Connected via female connector 8 on the Dirk Merbold controller.
17. Micro switch for the retraction activation of the gear motor.
Connected via female connector 7 on the Dirk Merbold controller.
18. Micro switch for the extension deactivation of the gear motor.
Connected via plug 6 on the Dirk Merbold controller.
19. Micro switch for the retraction deactivation of the gear motor.
Connected via female connector 5 on the Dirk Merbold controller.
Aside is a second micro switch to cut-off the power supply of the tilt-servo when the ORBIS is fully
retracted.