![THIES 4.3811.00.000 Operating Instructions Manual Download Page 22](http://html1.mh-extra.com/html/thies/4-3811-00-000/4-3811-00-000_operating-instructions-manual_1106906022.webp)
4.3811.00.000_US-Anemometer-DSP_eng.doc
22 - 26
021511/10/06
10 Predefined Data Telegram
Wind velocity, direction, acoustic virtual temperature, status and check sum
Command: TR00009
Telegram structure "Gamesa" :
!iivvvdddttttwfR
Ch. No.
Character set Function
1
(!)
!
Response character
2
(i)
0
•••
9
Identifier
3
(i)
0
•••
9
Identifier
4
(v)
0
•••
9
Wind velocity * 10
1
m/s
5
(v)
0
•••
9
Wind velocity * 10
0
m/s
6
(v)
0
•••
9
Wind velocity * 10
-1
m/s
7
(d)
0
•••
9
Wind direction * 10
2
degree
8
(d)
0
•••
9
Wind direction * 10
1
degree
9
(d)
0
•••
9
Wind direction * 10
0
degree
10
(t)
+
•••
−
Leading sign
11
(t)
0
•••
9
Temperature * 10
1
°C
12
(t)
0
•••
9
Temperature * 10
0
°C
13
(t)
0
•••
9
Temperature * 10
-1
°C
14
(w)
ASCII
Status byte, see item 6.2.2
15
(f)
ASCII
Check sum, see item 6.2.1
16
(R)
0D
HEX Carriage Return