background image

6   

EN

EN

   7

/ ViVi

®

 Helmet

/ ViVi

®

 Helmet

© THI GmbH 2018/09

REF 20602 | Rev-03

1

AC/DC POWER ADAPTOR

 - with multiple AC Heads.

2

POWER LED

 – A blue LED on the power adaptor indicating power ON.

3

AC HEADS

 – 4 diff erent power plugs for country specifi c use. Consult 

the user guide of the power adaptor how to install a suitable AC head. 

4

ADAPTOR CORD

  –  Connect  the  DC  connector  on  the  adaptor  cord 

with the battery charger. 

5

BATTERY CHARGER

 – designed to charge 4 battery packs REF 60401 

simultaneously. Use the charger to store battery packs between op-
erations. 

6

CHARGING BAY

  –  Insert  the  battery  pack  into  the  charging  bay  to 

connect the battery with the charger. Ensure correct orientation of the 
battery. 

7

BATTERY PACK

 – a belt clip helps to secure the battery pack on the 

body.

8

BATTERY CONNECTOR

 – This build in connector is used to connect the 

battery with the power cord of all 

ViVi

®

 helmets. Consult the section To Don 

a Surgical Helmet how to secure the power cord into the battery pack. 

9

CHARGING CONTACTS

  –  Ensure they  are  dry  and  clean when  con-

necting.

10

POWER LED

 – A green LED on the battery charger indicating power 

ON.

11

CHARGING INDICATION

  –  Each  charging  bay  is  equipped  with  a 

multi-color LED light indicating charging status. 

   Fully charged
   Charging

   Error

FEATURES - BATTERY AND CHARGER

   

Li-ion

 

SPECIFICATIONS (CONTINUED)

GUIDANCE AND MANUFACTURER‘S DECLARATION - ELECTROMAGNETIC EMISSIONS

ViVi

®

 Helmet REF 80100 and 80120 are intended for use in the electromagnetic environment specifi ed below. 

The customer or the user of 

ViVi

®

 Helmet REF 80100 or 80120 should assure that it is used in such an environment.

EMISSIONS TEST

COMPLIANCE

ELECTROMAGNETIC ENVIRONMENT - GUIDANCE

RF emissions CISPR 11

Group 1

ViVi

®

 Helmet REF 80100 and 80120 use RF energy only for its internal function. 

Therefore, its RF emissions are very low and are not likely to cause any interfer-
ence in nearby electronic equipment.

RF emissions

Class A

ViVi

®

 Helmet REF 80100 and 80120 are suitable for use in all establishments 

other than domestic establishments and those directly connected to the public 
low-voltage power supply network that supplies buildings used for domestic 
purposes.

Harmonic emissions     

lEG 61000-3-2

Not Applicable

Voltage fl uctuations/fl icker emissions
lEG 61000-3-3

Not Applicable

BATTERY DISPOSAL/RECYCLING

WARNING:  

• 

ALWAYS  follow  the  current  local  recommendations  and/or  regula-
tions governing environ-mental protection and risks associated with 
recycling or disposing of the equipment at the end of its useful life. 

• 

Per  the  European  Union  (EU)  Waste  Electronics  and  Electrical  Equipment 
(WEEE) Directive 2002/96/EC, product must be collected separately. 

• 

DO NOT dispose of as unsorted municipal waste. Contact your local distrib-
utor for disposal information. 

• 

Contains no hazardous substances, per RoHS standard. 

NOTES:

• 

This battery pack contains lithium ionide. After the end of its useful 
life, the battery must be disposed of by qualifi ed recycling or hazard-
ous materials handling operators. 

• 

DO NOT dispose the battery pack between other solid wastes. For dis-
posal and recycling information, refer to local operators responsible for 
recycling or handling hazardous materials.

8

11

9

7

7

3

2

1

4

10

5

   Fully charged
   Charging

   Error

6

CHARGING INDICATION 

NOTE: 

The battery status is indicated by a multi-colour LED (Pos.11) at each charging bay.

LED (POS.11)

STATUS INFORMATION

OFF

No battery in bay or no power.

Solid green

Stand by/battery present/battery full

Solid orange

Battery charging

Solid red

Error (see troubleshooting section)

Summary of Contents for ViVi 80100

Page 1: ... THI GmbH 2018 09 REF 20602 Rev 03 SURGICAL HELMET RX ONLY 80100 ViVi Helmet 80120 ViVi Helmet w Headlight ENGLISH EN DEUTSCH DE ITALIANO IT INSTRUCTIONS FOR USE ...

Page 2: ...tended to be used as a respiratory protec tion device The materials contained within this device are not known allergens However if an allergic reaction occurs contact a physician FOR USE WITH Rechargeable Battery Pack See Accessories section DESCRIPTION In addition to pulling in pushing out and circulating fresh air throughout the surgical helmet the helmet stabilizes the face shield of a surgica...

Page 3: ... handle is used to direct the headlight beam 13 HEADLIGHT CONTROL BUTTON Available on the headlight helmet model only Push the button to switch the headlight on off 14 POWER CABLE This build in power cable is used to connect all helmet models with the battery pack See the Accessories section 7 9 13 14 4 5 8 INSPECTION AND TESTING WARNINGS Only individuals trained and experienced in the maintenance ...

Page 4: ...ns to fog during use see the Troubleshooting section TO USE A SURGICAL HELMET WITH A HEADLIGHT 9 Push the headlight button to switch the headlight on off fig 9 WARNINGS Keep your fingers away from the headlight body during operation Avoid looking straight into the light beam 10 Adjust the headlight beam direction with the headlight adjustment handle fig 10 TO CONTROL FAN SPEED All ViVi helmets provide...

Page 5: ...e additional com fort one set per case 50785 NOTE For a complete list of accessories contact your distributor TROUBLESHOOTING WARNING DO NOT service this equipment unless otherwise specified If you require service contact your local distributor PROBLEM CAUSE ACTION The fans fail to provide air flow The battery pack is not charged or is damaged Change or replace the battery pack The battery is not co...

Page 6: ...ources of heat and humidity 2 Connect the DC connector on the adaptor cord Pos 4 with the battery charger CAUTION DO NOT connect power adaptors other than provided by THI to your battery charger 3 Plug the power adaptor into the mains outlet using the AC head suitable for your power system 4 Check if the power LED Pos 2 on the power adaptor and the power LED Pos 10 on the battery charger are ON 5 ...

Page 7: ... emissions CISPR 11 Group 1 ViVi Helmet REF 80100 and 80120 use RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interfer ence in nearby electronic equipment RF emissions Class A ViVi Helmet REF 80100 and 80120 are suitable for use in all establishments other than domestic establishments and those directly connected to the public low ...

Page 8: ...NWEISE Die Operationshelme sind nicht zur Verwendung als Atemschutzausrüs tung bestimmt Die in diesem Gerät enthaltenen Materialien sind nicht als Allergene be kannt Falls jedoch eine allergische Reaktion auftritt kontaktieren Sie bitte einen Arzt ZUR VERWENDUNG MIT Wiederaufladbaren Batterien Siehe Abschnitt Zubehör BESCHREIBUNG Neben dem Ansaugen Absaugen und der Zirkulation von Frischluft dient ...

Page 9: ... des Lichtstrahls 13 LICHT SCHALTKNOPF Erhältlich nur beim Lichthelm REF 80120 Drücken Sie den Knopf zum AN AUSSCHALTEN des Lichts 14 VERBINDUNGSKABEL Verwenden Sie dieses Verbindungskabel um den Helm mit der Batterie zu verbinden Siehe Abschnitt Zubehör 7 9 13 14 4 5 8 INSPEKTION UND TEST WARNHINWEISE Nur in der Wartung von wiederverwendbaren Medizinprodukten geschulte und erfahrene Personen soll...

Page 10: ...ung im OP vertraut Nun können Sie sich für die OP waschen und eine Haube oder eine Toga an ziehen Siehe Gebrauchsanweisung zum Anziehen der Haube oder der Toga Wenn das Visier während der Verwendung beschlagen sollte lesen Sie bitte den Abschnitt Fehlerbehebung VERWENDUNG EINES OPERATIONSHELMES MIT LICHT 8 Drücken Sie den Knopf zum AN AUSSCHALTEN des Lichtes Abb 9 WARNHINWEISE Halten Sie Ihre Fing...

Page 11: ...ICHNUNG ARTIKEL NR Wiederaufladbare Batterie 60401 ViVi Comfort Pads Ein Set von Einmal Polstern wird für einen besseren Tragekomfort auf der Innenseite des Helmes montiert ein Set pro Packung 50785 HINWEIS Für eine vollständige Zubehörliste kontaktieren Sie bitte Ihren Ver tragshändler FEHLERBEHEBUNG WARNHINWEIS Gerät NICHT WARTEN soweit nicht anders angegeben Wenn Sie ein Service benötigen kontak...

Page 12: ...den Netzadapter in die Netzsteckdose und verwenden dabei den für Ihr Netzsystem passenden AC Stecker 4 Prüfen Sie ob die Power LED Pos 2 am Netzadapter und die Power LED Pos 10 am Ladegerät eingeschaltet sind 5 Legen Sie einen Batterie Pos 7 in eine der Ladebuchten Pos 6 ein HINWEIS Sorgen Sie dafür dass die Batterie richtig in die Ladebucht eingelegt wird Nur wenn die Ladekontakte Pos 9 mit ihren...

Page 13: ...MITÄT ELEKTROMAGNETISCHE UMGEBUNG LEITFADEN Hochfrequenz Emissionen CISPR 11 Gruppe 1 ViVi Helm REF 80100 und 80120 verwendet Hochfrequenz Energie nur für in terne Funktionen Deshalb ist die Hochfrequenz Strahlung sehr gering und ver ursacht wahrscheinlich keine Interferenz mit in der Nähe befindlichen Geräten Hochfrequenz Emissionen Klasse A ViVi Helm REF 80100 und 80120 sind zur Verwendung in all...

Page 14: ...ti medici infermieri tecnici chirurgici e tecnici di apparecchiature biomedicali Conservare e consultare il presente manuale di riferimento nel corso del ciclo di vita del prodotto NEL PRESENTE MANUALE SONO UTILIZZATE LE SEGUENTI CONVENZIONI AVVERTENZA Un AVVERTENZA evidenzia un problema relativo alla sicu rezza Rispettare SEMPRE queste informazioni per evitare lesioni al personale sanitario e o a...

Page 15: ... il fascio di luce della lampada 13 PULSANTE DI COMANDO DELLA LUCE Disponibile solo per il mo dello di casco con luce Premere il pulsante per accendere o spegnere la lampada 14 CAVO DI ALIMENTAZIONE Questo cavo di alimentazione inte grato è usato per collegare tutti i modelli di caschi al pacco batteria Consultare la sezione Accessori CARATTERISTICHE ISPEZIONE E TEST AVVERTENZE Unicamente le perso...

Page 16: ... un panno morbido inumidito con un disinfettante ospe daliero non abrasivo 3 Asciugare l apparecchiatura con un asciugamano privo di lanugine o con aria compressa ad uso medicale ISTRUZIONI AVVERTENZE Eseguire le ispezioni e i test consigliati come indicato nella sezione Ispezione e Test Utilizzare SEMPRE l apparecchiatura entro i valori delle condizioni ambien tali specificati Consultare la sezion...

Page 17: ... casco chirurgico AVVERTENZE con il casco chirurgico Utilizzare esclusivamente componenti e accessori approvati da THI GmbH GUIDA ALLA RISOLUZIONE DEI PROBLEMI AVVERTENZA NON effettuare operazioni di manutenzione su questo apparecchio salvo diversamente specificato Contattare il proprio rivenditore locale per informazioni sulla manutenzione PROBLEMA CAUSA INTERVENTO La ventola non fornisce un sufficie...

Page 18: ...37 kg 13 1 oz 0 41 kg 14 5 oz Velocità della ventola Ventola principale 3 925 4 775 rpm Ventola per espulsione aria esausta 5 885 rpm Tensione in ingresso 12 4 16 4 V DC Protezione ingresso IP IPXO Modalità operativa Continua SPECIFICHE TECNICHE BATTERIA ModelLO REF 60401 Descrizione Pacco batterie ricari cabile Conformità alle normative europee CE Chimica cellulare Ioni di litio Tensione nominale...

Page 19: ...GUIDA Emissioni a RF CISPR 11 Gruppo 1 L Elmetto chirurgico ViVi Casco REF 80100 e l Elmetto chirurgico avanzato con illuminazione LED ViVi Casco con luce REF 80120 impiegano energia a RF solo per funzioni interne Pertanto le emissioni a RF sono di entità molto bassa e in genere non inducono interferenze in apparecchiature elettroniche vicine Emissioni a RF Classe A L Elmetto chirurgico ViVi Casco...

Page 20: ... 20602 Rev 03 20 IT ViVi Helmet Beep 1 6 2 7 3 8 4 9 5 10 Total Healthcare Innovation GmbH Gewerbestraße 4 9181 Feistritz im Rosental AUSTRIA phone 43 4228 30100 fax 43 4228 30100 20 mail office thigmbh at web www thigmbh at ...

Reviews: