background image

Tecma EasyFit Owner’s & Installation Manual

8

www.thetford.com                                                

Quick Start Label Installation / Installation de la plaque / Instalación de la etiqueta de inicio rápido

DANGER:

 Failure to use a Vented 

Loop in raw water pump installation 

sites  can  lead  to  water  flowing  into 

the toilet from the outside (siphon-

ing) which can cause loss of property 

and life!

!

Installation Planning, Con’t.

Planification de l’installation, suite

Planificación de la instalación, cont.

Bezel Installation

When planning the installation be sure to consider: 

 

■ Bezel placement wall thickness

 

■ Distance between toilet and bezel; the  

harness is 12’ in length 

DANGER HAZARD OF FIRE:

 

Always use recommended circuit breakers 

or fuses. Failure to follow the recommenda-

tions can result in fire. 

!

Required Tools

 

■ 1-1/4” hole saw

 

■ 3-1/2” hole saw

 

■ saber saw

 

■ 7/16” socket and ratchet or 7/16” wrench

 

■ Electric drill

 

■ 1/8” drill bit

DANGER :

 Négliger de poser une 

boucle de ventilation dans une instal-

lation à eau non traitée risque  de 

siphonner l’eau de l’extérieur vers la 

toilette et d’entraîner des pertes de vie 

et pertes matérielles!

!

Installation de la plaque

Lors de la planification de l’installation, prenez en 

compte : 

 

■ l’épaisseur du mur où sera installée 

la plaque 

 

■ La distance entre la toilette et la plaque;  

la longueur du faisceau de câbles est de 

3,7 m (12 pi)

DANGER RISQUE D’INCENDIE :

  

N’utilisez que les disjoncteurs et fusibles 

recommandés pour éviter tout risque 

d’incendies.

!

Outils requis

 

■ Scie emporte-pièce de 32 mm (1-1/4 po)

 

■ Scie emporte-pièce de 89 mm (3-1/2 po) 

 

■ Scie sauteuse

 

■ Clé à cliquets et douille 7/16 po ou clé 

7/16 po

 

■ Perceuse électrique

 

■ Mèche 1/8 po

PELIGRO:

 Si no se usa una válvula 

antisifón en los sitios de instalación 

de la bomba de agua bruta, el agua 

podría fluir (sifonear) hacia el inodoro 

desde la parte exterior de la embar-

cación, ¡con consecuentes posibles 

daños materiales y muertes!

!

Instalación del marco

Al hacer los planes de instalación, recuerde tomar 

en cuenta: 

 

■ El espesor de la pared de colocación  

del marco

 

■ La distancia entre el inodoro y el marco; el 

arnés tiene una longitud de 3.7 m (12 pies)

PELIGRO DE INCENDIO:

 

Utilice 

siempre los interruptores automáticos y 

fusibles recomendados. De no observarse 

esta advertencia, podría haber riesgos  

de incendio.

!

Herramientas requeridas

 

■ Serrucho de calar de 32 mm (1-1/4 pulg.)

 

■ Serrucho de calar de 89 mm (3-1/2 pulg.)

 

■ Sierra de vaivén

 

■ Dado y trinquete de 7/16 pulg. o llave 

de 7/16 pulg.

 

■ Taladro eléctrico

 

■ Broca de 1/8 pulg.

Press Either Button

Press 1 Second

2. Symbols Flash

See Owner’s Manual 

•    Apply label to under toilet lid  •    Part No. 38592 Rev. A 

Prevent Pump Damage: 

Flush ONLY organic materials!

Or

3. 

Release 

when 

water 

reaches 

desired 

depth

1. Press & Hold

F LUSH

ADD 

WATER

S ET  

WATER  

L EVEL

R ETURN  

TO 

NORM AL 

USE

E MPTY  

B OWL

CAUTION

Press Either Button

Press 1 Second

2. Symbols Flash

See Owner’s Manual 

•    Apply label to under toilet lid  •    Part No. 38592 Rev. A 

Prevent Pump Damage: 

Flush ONLY organic materials!

Or

3. 

Release 

when 

water 

reaches 

desired 

depth

1. Press & Hold

F

LUSH

A

DD

 

W

ATER

S

ET

 

W

ATER

 

L

EVEL

R

ETURN

 

T

O

 

N

ORM AL

 

U

SE

E

MPTY

 

B

OWL

CAUTION

T000007A

Summary of Contents for TECMA EasyFit Premium

Page 1: ...ctricit soient ex cut s par un professionnel muni d une licence Un permis local et le respect du code sont exig s N utilisez que les DISJONCTEURS FUSIBLES ET CALIBRES DE C BLES RECOMMAND S PAR l ABYC...

Page 2: ...n ou la section D pannage de ce manuel N utilisez QUE des accessoires de montage en ACIER INOXYDABLE NE L INSTALLEZ PAS SANS INS RER LES DOUILLES DE MONTAGE EN PLAS TIQUE DANS LES TROUS Un montage inc...

Page 3: ...e 19 mm 3 4 pulg de di metro m n si se requiere V lvula antisif n de 38 mm 1 1 2 pulg de di metro m n si se requiere Manguera de suministro de agua de calidad mar tima de 19 mm 3 4 pulg de di metro Ma...

Page 4: ...Deutsch Contact femelle 0462 201 16141 4 Fiche DT06 2S 2 Verrouillage du coin W2S 2 D Deutsch Broches 0460 202 16141 4 Prise DT04 2P 2 Verrouillage du coin W2P 2 Fils coupl s d alimentation F Deutsch...

Page 5: ...e requiere Instalaci n de agua bruta Tuber a de suministro de agua de 13 mm 1 2 pulg de di metro Instalaci n de agua dulce V lvula antisif n de 38 mm 1 1 2 pulg de di metro m n si se requiere Manguera...

Page 6: ...ine installation eau non trait e A R servoir d eau installation eau douce B Pompe eau d une autre marque que Thetford installation eau non trait e B1 Pompe refoulante d eau douce installation eau douc...

Page 7: ...tte EasyFit doit tre install e un endroit situ au dessus du r servoir d eaux us es Une l vation maximale de 183 cm 6 pi entre la toilette et le r servoir d eaux us es n aura pas d effet sur son foncti...

Page 8: ...ls requis Scie emporte pi ce de 32 mm 1 1 4 po Scie emporte pi ce de 89 mm 3 1 2 po Scie sauteuse Cl cliquets et douille 7 16 po ou cl 7 16 po Perceuse lectrique M che 1 8 po PELIGRO Si no se usa una...

Page 9: ...installation needs INSTALLATION INSTALLATION INSTALACI N FRESH WATER Single or Multiple Toilets EAU DOUCE Une ou plusieurs toilettes AGUA DULCE Inodoros individuales o m ltiples 1 Automatic Fresh Wate...

Page 10: ...NP J Place 1 in permanent position trace outline Placez 1 dans sa position permanente tracez son contour Colocar 1 en posici n permanente trazar per metro ART00212 1 1 1 1 8 drill bit M che de 1 8 po...

Page 11: ...desde la parte exterior de la embarcaci n con consecuentes posibles da os materiales y muertes Para determinar si se requiere una v lvula antisif n consulte Consideraciones referentes al agua bruta e...

Page 12: ...exi n a tierra Wall Switch Wiring Select wall switch location convenient to toilet Cut hole 2 5 8 x 3 3 4 and drill holes for mounting screws Side C t Lado 35 9 mm 3 23 82 mm 4 8 122 mm 3 70 94 mm 2 6...

Page 13: ...esi n Montage des capteurs du r servoir Mod le Plus seulement Capteur de pleine capacit Capteur de mi niveau en option Nettoyez la surface lat rale sup rieure du r servoir peu pr s sur l axe gauche dr...

Page 14: ...ritant If contact occurs rinse eyes with water for 15 minutes Keep out of reach of children La graisse di lectrique peut tre irritante pour les yeux En cas de contact rincez vous les yeux avec de l ea...

Page 15: ...l lectrorobinet ou de la pompe lectrorobinet mod les eau douce seulement ou pompe mod les eau non trait e seulement maximum 15 A Deux fils un bleu et un noir du c ble du bo tier de commande au c ble...

Page 16: ...emium and premium plus have differant wall switches Both have the ADD WATER and FLUSH buttons but only the premium plus has the tenk sensor lights located at the bottom of the switch T000029A Premium...

Page 17: ...de descarga El inodoro tiene dos modos de funcionamiento marino y residencial Se env a en el modo marino que deja la taza con una m nima cantidad de agua en el sif n hidr ulico al fondo de la taza El...

Page 18: ...agram to enter water refill programming mode Pour changer de mode de fonctionnement rendez vous en haut de ce sch ma pour entrer en mode de programmation de remplissage d eau Para cambiar los modos de...

Page 19: ...er de mani re optimale avec des pompes de r gime avoisinant les 10 litres 3 gallons par minute similaires la pompe fournie Les pompes de r gime inf rieur fourniront une vidange moins nergique alors qu...

Page 20: ...ant que le r servoir ne d borde La dimension et la forme du r servoir d eaux us es d terminent le nombre de fois qu elle peut tre utilis e Contactez votre fabricant pour obtenir de plus amples renseig...

Page 21: ...verrouillage Le verrouillage de la chasse d eau s enclenche normalement lorsque le r servoir d eaux us es est presque plein Dans ce cas si l on appuie sur le bouton de chasse d eau le symbole de r se...

Page 22: ...ttoyez la toilette fond ainsi que les tuyaux en faisant circuler une solution d Aqua Kem de SupremeGreen ou d Aqua Clean de Thetford D sodorisants Les d sodorisants pour r servoir d eaux us es de Thet...

Page 23: ...t tripped Ensure all electrical connectors to water pump are fully mated Water supply has been turned off Open water supply valves or reconnect power to supply pump Solenoid not plugged into relay mod...

Page 24: ...blage dans l embarcation L eau ne p n tre pas dans la cuvette durant la chasse ou le cycle d ajout d eau Conduite d arriv e d eau tordue ou non raccord e V rifiez que la conduite d arriv e d eau est...

Page 25: ...no se haya disparado el fusible interruptor autom tico Aseg rese de que los conectores el ctricos a la bomba de agua est n totalmente insertados Se cerr el suministro de agua Abra las v lvulas de sumi...

Page 26: ...enoid 12V or 24V lectrorobinet 12 V ou 24 V Solenoide 12 V o 24 V 11 Water Pump Kit 12V or 24V Ensemble de pompe 12 V ou 24 V Juego de bomba de agua 12 V o 24 V 12 Discharge Tube Kit Ensemble de tuyau...

Page 27: ...Tecma EasyFit Owner s Installation Manual 27 www thetford com...

Reviews: