15
INSTALLATION
Fig 4 - Cross Section View of Appliance Mounted in a Worktop
30mm Minimum air gap from lowest part under the hob.
Non – combustible material.
Vent – 8mm x 100mm minimum.
Gas dispersal hole (Ø12mm Minimum, Ø25mm Maximum).
Ventilation
This appliance is suitable for installation into Holiday Homes, Touring Caravans
and Boats. In all cases the national standards with regard to ventilation for the
particular vehicle into which the appliance is to be installed must be adhered to.
AS/NZS 5601.2 “LP Gas installations in caravans and boats for non-propulsive
purposes” specifies appliances be installed in accordance with the
manufacturer’s instructions.
Location of Appliance
This appliance may be installed in a kitchen/kitchen diner but NOT in a room
containing a bath or a shower. LP gas appliances must not be fitted below
ground level, e.g. not in a basement