pg. 35
PRESSOSTATO LATO FUMI
CIRCOLATORE
ASPIRATORE
RIARMO 100°C
TERMOSTATO SICUR.
MOTORE PULIZIA
MOTORE CARICAMENTO
CIRCOLATORE
220
-24
0V
50 H
z
1-4 Termostato Ambiente
1-6 Comando manuale retro
3-5 Altoparlante
1-2 Cronotermostato
FLUSSOSTATO
( OPTIONAL )
VALVOLA
DEVIATRICE
( OPTIONAL )
6
2 4
1
5
3
6 4 2
5 3 1
BRUCIATORE
RESISTENZA
PELLETS
AGGIUNTIVO
FUMI
Fusibile 3,15
1
2
O
N
Fus
ibile
3,15
A
Fusibile 3,15
TERMOSTATO 42°C
PRESSOSTATO
LATO ACQUA
TERMOCOPPIA
PER RADIOCOMANDO
SELETTORE CODICI
MICROPROCESSORE
SCHEDINA
TRASMETTITORE
RADIOCOMANDO
SCHEDINA RICEVITORE
FLASH VOCI
SCHEDINA
2
Fusi
bile
1A
1
O
N
9 VOCAL ALARMS
9 VOCAL ALARMS
9 VOCAL ALARMS
9 VOCAL ALARMS
9 VOCAL ALARMS
The heater / boiler is programmed to communicate 4 fundamental alarms. The vocal alarm is transmitted 4 times in rapid succession . It is
transmitted in the following languages: Italian, English, German, French. These situations are repeated two more times a few minutes apart. If
, however, the alarm is zeroed it will not be communicated.
The alarms are :
Pellets finished
+ the same alarm in the other 3 languages
Incorrect start up
+ the same alarm in the other 3 languages
General clean
+ the same alarm in the other 3 languages
Blocked smoke outlet
+ the same alarm in the other 3 languages
Insufficient water pressure
+ the same alarm in the other 3 languages
In detail:
Pellets finished
: is communicated when the temperature during the
RUNNING
mode drops below 42 °C.
This indicates that the appliance is switching off due to lack of pellets.
Incorrect start up
: is communicated if after the start up phase the temperature does not rise above 42°C.
General clean
:
is indicated after the insert has operated for over 1800 hours.
Blocked smoke outlet
: this occurs when the smoke outlet is partially blocked.
Insufficient water pressure
: the pressure in the boiler has dropped below 0.3 bar. see para. 5.1.7),
To reset the alarm the fire must be out, disconnect the electric power supply, wait 2 seconds and power up the generator once again.
1 0
1 0
1 0
1 0
1 0
ELECTRICAL WIRING
ELECTRICAL WIRING
ELECTRICAL WIRING
ELECTRICAL WIRING
ELECTRICAL WIRING
If another heater / boiler is installed in the vicinity of this heater then the
code selector in both the power board and the handheld radio control will
have to be reset; this is necessary to prevent interferences with the
operation of the two appliances. The code set in out products is standard.
If you wish to alter the transmission code act on the selectors in the power
board and the handheld radio control, making sure that they are set
identically.(see para. 5.1.12).
A DATA ANALYSIS of all the variables as described in para. 5.1.6 must be
carried out before the change can be activated.
PALMARE GESTITO VIA ONDE RADIO
SELETTORE CODICI PER RADIOCOMANDO
ON
1
2
ON
1 2
KEY
Code selector for handheld radio control
controlled by radio waves
Fuse
Smoke suction unit
Burner cleaning motor
Reset thermostat 100°C
Pellet feed motor
Heater
Additional ricirculating pump
Circulating pump
Diverting valve (optional)
Flow switch (optional)
Thermocouple
Room temperature thermostat
Chronothermostat
Rear manual control
Loudspeaker
Smoke side pressure switch
Thermostat 42°C
Thermocouple
Water side pressure switch
Transmitter board
Remote control receiver card
Voice flash card
Microprocessor
Radio control code selector
LEGENDA
Selettore codici per radiocomando
palmare gestito via onde radio
fusibile
aspiratore fumi
motore pulizia bruciatore
termostato sicur. riarmo 100°C
motore caricamento pelletts
resistenza
circolatore aggiuntivo
circolatore
valvola deviatrice (optional)
flussostato (optional)
termocoppia
termostato ambiente
cronotermostato
comando manuale retro
altoparlante
pressostato lato fumi
termostato 42°C
termocoppia
pressostato lato acqua
schedina trasmettitore
schedina ricevitore telecomando
schedina flash voci
microprocessore
selettore codici per radiocomando