To install the safety heat exchanger remove the
vertical door, the left side together with its
insulation and the vertical upright that holds the
door together with its screws as indicated.
Slide in the heat exchanger (1) and secure it to
the boiler using the hardware (2) provided.
Close the hole with the plug (3). By installing a
thermal relief valve the excess heat is absorbed
as soon as the central heating cooker rises to
excessive temperature values due to external
causes. This function is called fast disconnection
phase.
45
0 m
m
se
pa
re
te
in
le
gn
o
450 mm se
soffitto in legno
soffitto in muratura
250 mm se
450 mm for a timber ceiling
250 mm for a masonry ceiling
450 mm for a timber wall
4 . 2
4 . 2
4 . 2
4 . 2
4 . 2
MOUNTING
MOUNTING
MOUNTING
MOUNTING
MOUNTING THE SAFETY HEA
THE SAFETY HEA
THE SAFETY HEA
THE SAFETY HEA
THE SAFETY HEAT EX
T EX
T EX
T EX
T EXCHANGER
CHANGER
CHANGER
CHANGER
CHANGER
(OPTION
(OPTION
(OPTION
(OPTION
(OPTIONAL) (ONL
AL) (ONL
AL) (ONL
AL) (ONL
AL) (ONLY FOR 25 - 30 - F25 - F30)
Y FOR 25 - 30 - F25 - F30)
Y FOR 25 - 30 - F25 - F30)
Y FOR 25 - 30 - F25 - F30)
Y FOR 25 - 30 - F25 - F30)
A vital aspect to consider is that the flooring of the room in which the central
heating cooker is installed must be capable of bearing the weight of the
central heating cooker.
CAUTION: The room in which the central heating cooker is installed must be
adequately ventilated (1300 m
3
/h). Ensure that there is always a minimum
75mm
safety gap between the central heating cooker and walls
or
combustable materials
. If inflammable items are positioned near the central
heating cooker (matchboarding, furniture, curtains, wall hangings, sofas,
etc...), this gap must be increased considerably. Adhere to the recommended
minimum distances illustrated in the drawing on the right. It is permissible to
install the heater near materials that are sensitive to heat as long as suitable
insulating protection is placed between the material and the heater (ref. UNI
10683).
For inset installations ensure that the top cast iron cornice is insulated from the surrounding
furnishings by means of lateral air spaces
or compressed vermiculite insullation board
If you wish to integrate your central heating cooker with your kitchen furnishings or with a particular furnishing arrangement
remove the fold-away towel rack by undoing the 2 screws as illustrated in the figure below and then mount the enamelled
casing (only for models 25 - 30 - F25 - F30 ) . It is also advisable to apply
75mm
spacers to the sides of the central heating
cooker to prevent the heat from the top cast iron cornice from
damaging
the
adjacent
furniture.