User’s manual
GB
GB
72
Problem encountered
Check to be made
The radiator surface is
very hot
It is normal that the radiator should be hot when it is in
operation, but the maximum surface temperature is limited
in accordance with the NF Electricity performance standard.
However, if you think that your radiator is still too hot, make
sure that the power is appropriate for the surface area of
your room (we recommend 100W / m² for a ceiling height
of 2.50 m) and that the radiator is not placed in a draft that
would disturb its regulation.
There is a significant
difference between the
ambient temperature
in the room and
the equipment set
temperature
After 6h stabilisation, you can recalibrate your radiator by
doing a long press (3 sec) on
and and wait until «
OFFSET » is displayed.
Set the observed temperature difference by pressing the +
or - button and then confirm by pressing the button.
Example: If the ambient temperature is 20°C and the set
temperature is 18°C, add +2° to the «OFFSET » value.
8 - APPENDIX
8.1 Warning
- Do not cover the radiator, to avoid overheating and for security reasons
.
- Make sure that children are not leaning on the radiator surface and are not playing nearby
when it is in operation, since under some circumstances the surface of the radiator could
cause skin burns, particularly because their reflexes are not fully developed or they are
slower than for adults. If there is any risk, install a protection grill in front of the radiator.
- This radiator is not designed for use by persons (including children) whose physical,
sensorial or mental capabilities are limited, or persons without any experience or knowledge,
unless they are supervised or given prior instructions about use of the equipment by a
person responsible for their safety.
- Children should be monitored to make sure that they do not play with the radiator.
- Make sure that you do not insert objects or paper into the radiator.
- Whenever doing any work on the radiator, the radiator itself and the external power
manager (if there is one) should be switched off.
8.2 Identification of the radiator
Before calling our Before and After Sales Department, remember to identify the radiator
references. This informations are written on the name plate located on the right side of the
radiator.
A Standards, quality labels
B Trade name
C Commercial code
D Manufacturing reference
E Serial number
F Manufacturer’s number
Equateur2_1880-1585_interieur.indd 72