BEDROOM
HALL
DINING ROOM
MINIMUM RECOMMENDATIONS
EXISTING HOMES
NOTE:
Kitchens should be covered by a
self contained heat detector.
RECOMMENDED FOR ADDITIONAL
PROTECTION
Multi-family or mixed occupant
residence
(Tenancy building, student
accommodation)
Your FireAngel
Ⓡ
smoke alarm can also
be used in individual flats and bedsits,
providing the same conditions are met as
for a single-family residence. However,
there must already be a primary fire
detection system that meets regulatory
requirements for common areas such as
lobbies and hallways.
Institutions and Hotels
This includes motels, hospitals, day care
facilities, long-term health care facilities,
.
.
.
.
APPLICATION
WARNING:
Your FireAngel
®
smoke alarm
can be installed into a new build property
as additional protection to an existing
smoke detection system only. It cannot be
used as a substitute for a hard wired system
as required in new build properties. In this
type of property the building regulations
require alarms to be interlinked. You can
obtain further information from your local
fire service or building control department
at your local council offices. These sources
generally provide advice on new builds or
projects that require planning permission.
Your smoke alarm typically meets the
minimum requirements for family living
units in existing buildings, as long as at
least one unit is installed on each floor/
level of your property. In order to achieve
the earliest fire warning, we recommend
that a smoke alarm is fitted in all rooms
where the temperature is normally
between 4°C (40°F) and 38°C (100°F).
WARNING:
The alarm positions shown
are based on typical homes. Construction
and layout of individual dwellings will
vary, so this should be regarded only as a
guide. Check with your local fire station for
further guidance.