The unit will give an audible alarm 
consisting of 2 cycles of 3 loud beeps, then 
stop automatically.

The red LED on your alarm will flash 
rapidly during the audible signal.

NOTE: 

The test button accurately tests 

the alarm’s smoke sensing circuit, there is 
no need to test your alarm with smoke. If 
your smoke alarm fails to give an audible 
test signal, please refer immediately to the 
‘Troubleshooting’ section (see page 13).

WARNING:

 You should test your smoke 

alarm every week.

ALARM SMART 

SILENCE™

DANGER:

 If your FireAngel

®

 smoke alarm 

emits the full alarm signal and you are 
not testing the unit, the smoke alarm is 
warning you of a potentially dangerous 
situation that requires your immediate 
attention. Only use the alarm silence 
function after making sure that there is no 
fire. Do not block the vents on the alarm 

or disable the smoke alarm in any way, as 
this will remove your protection. Smoke 
alarms can sometimes react to cooking 
fumes or other non-emergency situations. 

Your smoke alarm features “Smart 
Silence™” technology. In the event of a 
known false alarm your smoke alarm can 
be temporarily silenced by briefly pressing 
the central test button. Your alarm will 
automatically return to full sensitivity 
within 10 minutes.

NOTE:

 If the level of smoke reaching the 

alarm is very high the alarm silence will be 
overridden and the alarm will continue to 
sound.

Briefly press and release the test button. 
The alarm sound will soon stop.

Your alarm will silence and enter 
into a reduced sensitivity mode for 
approximately 10 minutes.

.

Summary of Contents for FireAngel ST-625

Page 1: ...User Manual Smoke Alarm Model ST 625...

Page 2: ...1 800 523171 Email technicalsupport sprue com Web www fireangel co uk ST 625 GN3054R1 14 0333 CPR 292075 Smoke alarm devices EN 14604 2005 AC 2008 DOP SADOPST 625 01 Sprue Safety Products Ltd Vanguar...

Page 3: ...Battery replacement 8 Alarm test 9 Note This user manual is also available in large text and other formats Please email technicalsupport sprue com or call 0800 141 2561 for further information Alarm S...

Page 4: ...his user manual fully before installing and operating the alarm If you are installing this smoke alarm for use by others you must leave this manual or a copy of it with the end user SENSORTECHNOLOGY T...

Page 5: ...g smoke detection system only It cannot be used as a substitute for a hard wired system as required in new build properties In this type of property the building regulations require alarms to be inter...

Page 6: ...e read and understood this manual before installing your smoke alarm 1 Install Batteries IMPORTANT Before fitting your smoke alarm the batteries must be installed Remove the protective wrapper from th...

Page 7: ...drill holes With an appropriately sized drill drill the holes and insert the plastic fixing anchors supplied if needed Fit the base plate to the ceiling or wall using the screws provided 3 FitYour Fi...

Page 8: ...attery Condition Should your FireAngel smoke alarm enter a low battery condition the unit will emit an audible chirp once every 40 seconds When this occurs we recommend you replace the batteries immed...

Page 9: ...he alarm up to the base plate and push and rotate the alarm clockwise into position as shown Make sure that the unit is securely fitted After fitting your alarm to the base plate wait for 5 seconds fo...

Page 10: ...t requires your immediate attention Only use the alarm silence function after making sure that there is no fire Do not block the vents on the alarm or disable the smoke alarm in any way as this will r...

Page 11: ...mmediately SLEEP EASY Low battery warnings often start at night or when it may be inconvenient to replace the batteries You can silence the audible chirp for a period of 8 hours by pressing the test b...

Page 12: ...ke alarm once every week see AlarmTest Cleaning As a minimum your smoke alarm should be cleaned once every 3 months using your vacuum cleaner fitted with the soft brush attachment WARNING Your FireAng...

Page 13: ...en recently fitted and it still fails to self test then contact Technical Support on 0800 141 2561 or e mail technicalsupport sprue com Your FireAngel smoke alarm chirps intermittently Check the locat...

Page 14: ...rate time from the chirp a fault is indicated If within warranty contactTechnical Support see below Otherwise replace immediately You experience frequent unwanted alarms Check the location of your Fir...

Page 15: ...any replacement ST 625 alarm will last for the remainder of the period of the original warranty in respect of the alarm originally purchased that is from the date of original purchase and not from the...

Page 16: ......

Reviews: