4. Operating instruction
4.1 Operating the NL-24 Pro
You can start operating the NL-24 Pro as soon as it is connected to both the electricity mains and to an airsupply
which provides clean and dry compressed air set at a maximum of 6 Bar. Switch on the machine by pressing the
on/off (I-0) switch, which is placed on the back of the machine, to “on (I)”. Wait until the set temperature has
been reached, which will take about one minute.
Starting up:
At start up the display will show the Thermopatch logo.
The element is now heating up to the set temperature and the display will show information about the settings.
Stand-by
When the machine is idle for a longer period than the set time for Stand-by, it will go into power saving mode.
The factory set time for Stand-by is set after 15 minutes.
The heating element will be deactiveted if this function is enabled. De fabrieksinstelling voor Stand-by staat op
15 minuten.
4.1.1 The control unit and display
The display of the control unit will show the version number of the firmware on display; this will dissapear
after about 3 seconds and then it shows the last setting in which the machine was used. If any failures are
found at starting up, these will be shown in the display and the machine will not heat up.
See paragraph 4.4, page 8; the cause of the error code needs to be repaired first.
The display will show the actual temperature and is ready for use.
Auto on / off
Temperature
Time
Pressure
Increase / up
Decrease / down
ATTENTION!
The NL-24 Pro cannot be in operational mode if you want to change settings.