4.2 Interrupting the work cycle of the NL-24 Pro
In order to interrupt the work cycle of the machine at any time, push any button on the key board or the
emergency stop button which is placed on the sealing arm on the front end of the machine.
The machine will shut down immediately and will end the started work cycle and open up. To re-activate
the emergency stop button has to be turned clockwise (arrow). It will start up again and be ready for use
after reaching the set temperature.
4.3 Reading the counters
By p or - simultaneously the total counter will appear on display. This value cannot be re-set.
By p or -, either one of the two periodical counters can be entered. These can be re-set by keeping
the concering button pushed until 0 appears.
The day counter on display will be automatically reset after the machine is switched off.
4.4 Error messages
On display the following error codes can appear:
1 = open temperature sensor
2 = temperature sensor short circuit
3 = heating element defective
4 = pressure too low
5 = pressure too high
6 = safety frame activated