1 2 3 4
18 17 16 15 14 13 12 11 10
9 8 7 6 5 4 3 2 1
Phase
Neutral
Thermocouple
J
LIGHT BULB
STEAM
AL
ARM 1
E1
B1
E1:
Door micro switch
B1:
External audible alarm (buzzer)
1 2 3 4
18 17 16 15 14 13 12 11 10
9 8 7 6 5 4 3 2 1
Phase
Neutral
Thermocouple
J
LIGHT BULB
IGNITION
STEAM
GAS 1
E1
Q
E2
B1
E1:
Door micro switch
E2:
Flame sensor
B1:
External audible alarm (buzzer)
Q:
Burner
10.1.2 Oven: Gas
10.1.3 Oven: Wood
10. INSTALLATION
10.1 Electrical connections
11. DIMENSIONS
75,6
75,4
Panel openings
67,2 mm
67,2 mm
25 mm
10 mm
PACKAGING:
Materials used in the packaging of the Full Gauge Controls products are 100% recyclable. Be sure to dispose of using specialized
recycling facilities.
PRODUCT:
The components used in the Full Gauge Controls controllers may be recycled and reused if disassembled by specialized companies.
DISPOSAL:
Do not incinerate or dispose of the controllers that reached the end of their service life in household waste. Be sure to comply with the
existing legislation in your area relating to disposal of electronic waste. In the event of doubt, please contact Full Gauge Controls.
ENVIRONMENTAL INFORMATION
67
100,3
75
80
84,8
Front view
Side view
PRODUCT INSTALLATION PRECAUTIONS:
10.1.1 Oven: Electric
WARRANTY - FULL GAUGE CONTROLS
Products manufactured by Full Gauge Controls, as of May 2005, have a ten (10)-year warranty directly with the factory and one
(1) year before the reseller network, counted as of the date of consigned sale as stated on the invoice. After this said year before
the reseller network, the warranty shall continue to be executed if the instrument is sent directly to Full Gauge Controls. The
products are warranted in case of defects in workmanship making them unsuitable or inadequate to the intended applications. The
warranty is limited to maintenance of instruments manufactured by Full Gauge Controls, disregarding other kinds of expenses,
such as indemnity for damages caused to other equipment.
EXCEPTIONS TO WARRANTY
The Warranty does not cover expenses incurred for freight and/or insurance for sending the products with signs of defect or
malfunctioning to the provider of technical support services. The following events are also excluded from warranty: natural wear
and tear of parts, external damages caused by falls or inadequate packaging of products.
INVALIDATION OF WARRANTY
The product warranty shall lose validity, automatically, if:
- The instructions for use and assembly contained in the technical description and the installation procedures described in
Standard NBR5410 are not followed;
- The product is submitted to conditions beyond the limits specified in its technical description;
- The product is violated or repaired by a person not integrating the technical team of Full Gauge Controls;
- The damages are due to a fall, blow and/or impact, water damage, overload and/or atmospheric discharge.
USE OF WARRANTY
For using the warranty, the customer should send the adequately packaged product, along with the respective Invoice to Full
Gauge Controls. The customer will bear the freight cost for sending of the products. Also, as much information as possible with
regard to the defect verified should be sent, in order to facilitate the analysis, the testing and the performance of the service.
Those processes and any product maintenance shall only be performed by the Technical Support Services of Full Gauge
Controls, at the Company headquarters - Rua Júlio de Castilhos, 250 - CEP 92120-030 - Canoas - Rio Grande do Sul – Brazil.
Rev. 03
Before performing any procedure on this instrument, disconnect it from the power grid;
Ensure that it has adequate ventilation, avoid installation on control panels containing devices that could cause it to
operate outside its specified temperature range;
Install the product away from sources that may generate electromagnetic disturbances, such as: motors, contactors,
relays, electrovalves, etc;
IMPORTANT:
It is crucial to install the ignition module next to the burner and as far as possible from the electronic controller;
The ignition electrode must be installed at a distance of 5 mm from the burner;
The flame sensor must be installed at a distance of 5 mm from the burner and at least 50 mm from the ignition
electrode.
1 2 3 4
18 17 16 15 14 13 12 11 10
9 8 7 6 5 4 3 2 1
Phase
Neutral
Thermocouple
J
LIGHT BULB
STEAM
E1
B1
E1:
Door micro switch
B1:
External audible alarm (buzzer)
RESISTENCE 1
It is an accessory the main function of which is to store the parameters of
controllers. At any time you can load new parameters of a controller and
unload them on a production line (of the same controller), for example.
It is provided with three types of connections
for loading or unloading the parameters:
-
Serial RS-485:
It is connected by RS-485
network to the controller (only for those
controllers provided with RS-485).
- USB:
It is connected to the computer by
USB port, using the Sitrad Preset Editor.
- Serial TTL:
The controller may be
connected directly to EasyProg by Serial
TTL connection.
12. EasyProg* - version 2 or later
EASYPROG
*vendido separadamente