TROUBLE SHOOTING GUIDE
PROBLEM
POSSIBLE CAUSE
REMEDY
Red LED does
1. DC circuit power
1. Exchange the DC
not “flash”
connected in
circuit power.
reverse order.
“Light up” red
1. Has been triggered.
1. Press the
key..
LED does “flash”
Red LED
1. COM / 1 still under
1. Clear the trigger on the
illuminates and
trigger.
control panel or wait
device could
for the control panel to be
not be reverted
stopped automatically.
back to stand-by
by pressing the
2. The cable, which
2. Check the cable.
key..
is connected to the
control panel, is faulty.
Yellow LED will
1. Memory selected
1. Select the correct memory.
not stop flashing.
incorrectly.
Green LED does
1. Telephone line is not
1. Check that the Line Jack is
not flash when
not connected correctly. inserted correctly.
key is
pressed or when
2. There is a breakdown
2. Check there is a dialing tone
the wire control
in the telephone line.
from the extension. If there is
is triggered.
no tone contact the telephone
company to repair it.
SPECIFICATION:
Operating Voltage:
7.7 to 13.8 VDC
Operating Environment:
Temperature 0°C to 40°C
Stand-by Current:
17mA typically 25mA max. (at 12 VDC)
Alarm Current:
90mA typically 100mA max. (at 12 VDC)