PRODUCT WARRANTY: 

 

1.   This warranty is limited to goods purchased and installed in *Australia.  

Twelve (12) Months full warranty on parts and labour by Thermoline Scientific through its 
authorised dealers or service organisations, will repair or at its option replace any part found to 
contain a manufacturing defect in material or workmanship without charge to the purchaser for 
parts, service labour or any necessary shipping or cartage costs for parts only. This warranty 
does not apply to damage caused by accident, misuse, fire, flood, or acts of God. It does not 
apply to damage caused from  failure to properly install, operate or maintain the goods in 
accordance with the printed instructions provided. To obtain prompt warranty and service, 
simply contact Thermoline Scientific. 

 
2.  If warranty service is required, Thermoline Scientific will endeavour to have an authorised 

service organisation carry out the work if there is an available agent, however if it is decided to 
return the equipment to our main workshop then it is the customers responsibility to pay the 
freight cost of this return, Thermoline Scientific, after the repair, will return the goods at our 
cost, to the customer. 

The customer should always contact Thermoline Scientific for approval to return and 
seek advice as to the best and most cost effective method of return. 

 
3. 

*Export Warranty:

 Limited to replacement of 

Parts Only

. Supplied Ex Factory, Australia. This 

warranty does not apply to refrigeration compressor(s), that are not protected by Thermoline 
Scientific factory installed (VFP) Voltage Fluctuation Protection unit. 

 
4. 

Limitation of Liability:

  Except to the extent not permitted by law, Thermoline Scientific 

excludes all warranties, conditions and terms implied by law. If any implied warranty, condition 
or term does exist, Thermoline Scientific’s liability for breach of that implied term is limited, at 
the option of Thermoline Scientific, to replacement or repair of goods or part thereof, or 
payment of the cost of repairing or replacing the goods or any part of the goods. 
The buyer does not have, under any circumstances, any cause of action or right to claim or 
recover from Thermoline Scientific for, or in respect of, any loss or damage of any kind 
whatsoever, caused directly or indirectly by: 

  any defect in material or workmanship of, or any other defect whatsoever in, or unsuitability 

for, any purpose of the goods or any part of the goods; or 

  default or negligence on the part of Thermoline Scientific or of any employee,    

contractor or agent of Thermoline Scientific or of any person for whom 
Thermoline Scientific had legal responsibility relating to the supply, or otherwise 
concerning the goods or any legal part of the goods. 

5. 

The 12 month warranty period starts from

 the date the equipment is supplied. 

When making a claim for repairs under warranty please state the model number 
and serial number. These are printed on the compliance sticker, normally found 
on the front of the cabinet. Our records will show when the cabinet was 
despatched and if the warranty claim is valid. 

 

 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for TCH-150

Page 1: ...t Pty Ltd T A Thermoline Scientific ABN 80 000 859 129 10 12 Ross Place Wetherill Park N S W 2164 Australia P O Box 6862 Wetherill Park Delivery Centre N S W 1851 Australia Phone 02 9604 3911 Internat...

Page 2: ...pment be aware of the ALERT BOXES that appear throughout these operating instructions INDEX IMPORTANT INFORMATION Page 1 INDEX Page 1 2 PRODUCT WARRANTY Page 3 INTRODUCTION Page 4 THE MANUAL Page 4 UN...

Page 3: ...HANGING THE SET VALUE Pages 13 ADJUSTING THE VENTS Pages 14 15 SENSOR CORRECTION FOR CALIBRATION PURPOSES Page 16 MEASURING EQUIPMENT Page 16 ADJUSTING THE CALIBRATION OFFSET Page 17 MAINTENANCE CLEAN...

Page 4: ...stralia This warranty does not apply to refrigeration compressor s that are not protected by Thermoline Scientific factory installed VFP Voltage Fluctuation Protection unit 4 Limitation of Liability E...

Page 5: ...ese items could be included as part of the packing list if ordered Water supply bottle 25 litre bottle complete with hose connection fittings 1 x 4 pin plug for retransmission connection Circular char...

Page 6: ...d 10 amp power point WARNING Ensure that the electrical outlet is earthed is the correct voltage and capable of carrying the stated current Model TCH 150 is suitable for bench top or floor use whereas...

Page 7: ...HE CABINET DURING SERVICE ASSEMBLY INSTALLATION ASSEMBLY SHELVES Place the shelves at the required level The shelf runners are fixed at 100mm centres PERSPEX HOLDER This holder is provided so that the...

Page 8: ...er to gain access to the drain valve see photo 3 below The drain valve is shown in the closed position Note Prior to leaving the factory the water pressure regulator has been left fully open as it sho...

Page 9: ...of products within the range shown below in the control envelope NOTE Temperature and humidity inside the cabinet can only be controlled at temperatures above the ambient WARNING Do not use flammable...

Page 10: ...justable vents on top of the cabinet an air inlet and an air exhaust The operator can adjust these vents to increase or decrease the amount of ambient air that is mixed with the air inside the cabinet...

Page 11: ...P a g e 10 18 5 10 TCH 150 460 Figure 1 Section side view of cabinet showing air flow EXPLANATION OF CONTROLS Figure 2 Control Panel Layout...

Page 12: ...and quick recovery times Maximum recommended temperature is 80 C Humidity control This is a Eurotherm 3216 microprocessor based instrument with digital indication of set humidity and operating humidi...

Page 13: ...off the fan and heating elements when the door is open 4 Position the mains switch to the ON position reset and immediately both controllers will go through a short initiation period the two displays...

Page 14: ...e alarm will switch off all forms of heating if the actual temperature exceeds the set temperature by 2 0 C This will be indicated by a red flashing indicator and a scrolling message of Over Temperatu...

Page 15: ...gher humidity both vents will be closed for lower humidity the vents will be more open The ambient temperature and humidity will have a large bearing on the temperature and humidity attainable inside...

Page 16: ...P a g e 15 18 5 10 TCH 150 460...

Page 17: ...the operator access level so that it can be used to correct the displayed operating value If adjustments need to be made use the calibration procedure below MEASURING EQUIPMENT Ensure that the equipme...

Page 18: ...e should be carefully considered If in doubt return the value to zero and recalculate the offset value Press the scroll key again to return to the original screen The offset value will have changed to...

Page 19: ...rocess There are several chemicals which will attack the surface of stainless steel plus the lack of oxygen at the surface will cause rusting corrosion and pitting Note Deionised water is particularly...

Page 20: ...lly there is still enough pressure reduction through the valve even when fully open to reduce bounce When mains water is connected to the cabinet As described previously when town water is connected a...

Page 21: ...65 Fan motor Betts 50D503 86A 5 70 Centrifugal blower wheel 5 66 Cooling fan blade 4 30 MRA Bit 02 pressure regulator 4 32 Water solenoid valve L171B13 ZZ23A 1 8 TECHNICAL ASSISTANCE If you require ad...

Page 22: ...the cabinet for connection to an outside monitoring system which is able to accept the 4 20mA signals representing 0 0 to 100 0 C and 0 to 100 RH Maximum load to be applied to the analogue output is 5...

Reviews: