Flask size

Size

Liquid volume

Max Speed(rpm)

50ml

50ml

550

100ml

100ml

550

150ml

150ml

550

550

200ml

200ml

250ml

250ml

500

500ml

500ml

400

1000ml

1000ml

280

Max Flask

Capacity

49

25

25

18

18

10

7

500ml

480

7

2000ml

2000ml

230

4

1000ml

430

4

3000ml

3000ml

200

4

1500ml

430

4

5000ml

5000ml

150

2500ml

280

2

2

Note:

1) The flask clamps (

2L) can be placed anywhere on the universal (aluminum)

     platform, even if the load is not balanced. 

2) Please refer to the "Liquid Volume" table in the specifications section for the
     maximum load. 

 

Table 2-4. 

Maximum Shaking Speed and Flask Capacity on 18 inch (aluminum)

                    Platform

Note:

1) The flask clamps (<2L) can be placed anywhere on the 18inch (aluminum)
     platform, even if the load is not balanced. 

2) Please refer to the "Liquid Volume" table in the specifications section for the
     maximum load. 

 

Section 3  Operation

3.1 Operations on the Control Panel

The unit has been designed with a “soft 
start/slow down” providing a 
smooth acceleration/ deceleration 
during operation. This feature will 
decrease splashing of solutions from 
vessels during operation.

Warning: 

The microprocessor control 

system may take 1 minute to 

synchronize the actual RPM of the 
universal (aluminum) platform to the 
desired RPM setting. Make sure that all 
the flasks and test tubes are firmly 
fixed on the universal platform and the 
flask clamps are fasten securely 
with the screws.

1) Display LED: Shows time or speed

2) RPM indicator light: LED shows  

     current speed

3) TIME indicator light: LED shows 

     current time

4) WARN indicator light: Over-speed 

     alarm

5) RUN indicator light: The instrument is 

     running

6) RPM/TIME Key: While instrument is in 

     operation, press to change time and 

     speed display; when setting 

     parameter, press to change minutes, 

     hour or speed.

7) Up Arrow Key: Increases value. Hold 

     for 3 seconds to increase rapidly

8) Down Arrow Key: Decreases value. 

     Hold for 3 seconds to decrease 

     rapidly.

9)         Key: The power is On/Off.

10) Run/Stop Key: The instrument is 

running or stopped.

MaxQ 2000 CO2 Plus      10

 

Summary of Contents for MaxQ 2000 CO2 Plus

Page 1: ...r online thermofisher ca For Research Use Only Not for use in diagnostic procedures 2020 Thermo Fisher Scientific Inc All rights reserved All trademarks are the property of Thermo Fisher Scientific an...

Page 2: ...xtended Warranty for your Thermo Scientific products Whatever Thermo Scientific products you need or use we will be happy to discuss your applications If you are experiencing technical problems workin...

Page 3: ...al Cable Output current of Control Box Maximum Shaking Speed Section 3 Operation Operations on the Control Panel Speed and Time Settings Alarm System Section 4 Application Section 5 Safety Tips Sectio...

Page 4: ...xQ 2000 CO2 Plus Promotion Package for EMEA APAC includes CO2 resistant shaker 88881102B Universal Platform Flask Clamp Starter Kit Main Body Control Box General Power Adaptor US Plug CN Plug EU Plug...

Page 5: ...recessed countersink head screws 2 18inch aluminum platform 3 Main body of CO2 resistant shaker 3 Section 1 Unpacking and Installation 1 2 Universal Aluminum Platform Installation 1 4 Rubber Mat Plat...

Page 6: ...00 m Humidity 20 to 99 non condensing 2 2 Environmental Conditions Rotation Speed Load Timer Dimensions Weight Power Supply Others 5 Section 2 Overview 2 3 Safety Tips 1 Unplug and unload before movin...

Page 7: ...1000ml 1000ml 250 2000ml 2000ml 200 3000ml 3000ml 200 5000ml 5000ml 150 Flask size Size Liquid volume Max Speed rpm 50ml 50ml 600 600 600 600 600 580 550 500 470 430 450 400 450 400 100ml 100ml 150ml...

Page 8: ...has been designed with a soft start slow down providing a smooth acceleration deceleration during operation This feature will decrease splashing of solutions from vessels during operation Warning The...

Page 9: ...operation the alarm will sound after 10 seconds if the unit has not begun shaking In addition the alarm will sound and stop for the speed over 650 rpm after 2 seconds 2 Once the shaker begins to alarm...

Page 10: ...e power cord 2 Remove the platform with 4 screws 3 Remove top plate with 7 screws 4 Use 70 ETOH to clean the inner area 5 All allow the unit to dry for one hour reassemble unit and operate normally Se...

Page 11: ...6mm 1 88881122B 18inch Aluminum platform N A 360x305x10 88881123 Rubber Mat platform 10 130x90x15 88881124 96 well microplate holder Table 6 2 18inch Aluminum Platform Description 50ml clamp 100ml cla...

Page 12: ...Accessories Section 7 Troubleshooting To troubleshoot the unit refer to the table below If your problem persists contact your local sales service representative Indicator off No reaction No rotating...

Page 13: ...the original warranty period The Technical Services Department must give prior approval for return of any components or equipment At Thermo s option all non conforming parts must be returned to Thermo...

Reviews: