3.6 Operation (Remote Control)
Igniting the flame
* Open the gas shut-off cock that has been installed in the gas pipe to the unit.
* Press the “
O I
” switch on the gas control block to the “
I
” position.
* Turn the operating button on the gas control block into the
ON
position.
* Press the
OFF
and
(large) switches on the remote control at the same time. A short sound signal will
confirm commencement.
Short sound signals will then follow until the pilot light and main burner are ignited.
Once the main burner is ignited, the flame will adjust to its maximum height automatically.
3.7 Possible error messages
* Long sound signals during ignition: Receiver batteries are almost empty. (After this signal is heard, the unit
may be switched on approximately 10x more).
* 5 seconds of continuous sound signal: Error message. For example: one of the cables is not connected, the
“
O I
” switch is not in the “
I
” position.
* 5x short sound signal: The pilot light or main burner are not ignited.
Possible cause: air in the pilot pipes.
Important
If the pilot light is extinguished, wait at least 5 minutes before
repeating the steps above.
Piëzo Ignitter
(Manual)
Manual knob
Main valve knob
Microswitch
“
O I
” Switch
8 Wire Receiver Jack
Combination Control, Cover
Summary of Contents for Trimline 100
Page 14: ...Page 14 A B 6 4 2 3 1 7 5 9 6 8 11 10 12 100 100 2 3 1 9 6 7 5 4 8 6 12 11 10 ...
Page 17: ...Page 17 ...
Page 26: ...Page 26 H G M N O E B D I A F C J K L P ...
Page 27: ...Page 27 1 2 1036 1037 1039 4 3 1038 ...
Page 28: ...Page 28 14 6 13 5 ...
Page 29: ...Page 29 7 8 ...
Page 30: ...Page 30 1036 A B ...
Page 31: ...Page 31 1037 1038 A B ...
Page 32: ...Page 32 1039 A B ...
Page 33: ...Page 33 Pebles Carara 10 9 ...
Page 34: ...Page 34 16 15 14 13 12 11 ...
Page 35: ...Page 35 ...
Page 36: ...Page 36 TTI d o o Thermo Technology International ...