2.3
Main components stationary used
heater (vegetable oil or biodiesel
(fig. 3)
A Cover
B Flue connection
C Combustion chamber
D Connection for hot air fan
E Identification plate
F Fuel filter
G Switch box
H Fuel tank
I
Fuel pump
J Drain cock
K Fill filter
L Fuel pipe
M Return line
N Inspection window
O Fuel supply pipe
P Heat distributor with fan
Q Maximum thermostat
2.4
Main components of the burner
(fig. 4)
A Explosion window
B Combustion chamber
C Vaporisation ring
D Vaporisation section
E Combustion air ventilator
F Burner dish
G Overflow protection
H Fan thermostat
I
Thermostat pump - and oxygen motor
J Shovel
2.6
Thermostat
The Bio Energy has the following thermostats:
•
•
Maximum thermostat
The thermostat stops the fuel pump when
the combustion temperature gets too
high.
•
Fan thermostat
The thermostat starts up the hot air fan
as soon as the heater reaches the right
temperature. After switching off the
heater, the fan thermostat ensures that
the hot air fan keeps running, which cools
the heater. As soon as the heater has
cooled down, the fan thermostat switches
off the hot air fan.
2.7
Accessories
•
Flue with rain cap
3
PREPARATIONS
3.1
Removing the packaging
1. Remove packaging from the heater.
2. Remove packaging from the loose parts
in the combustion chamber.
3.2
Installation
1. Ensure that the used heater (vegetable
oil or biodiesel) is positioned horizontally.
2. Correctly attach the parts of the
combustion chamber, see fig. 4.
3. Open the filling cover and fill the tank with
fuel.
Caution
Only the following oil types may be
used in the stationary used
(vegetable oil or biodiesel) heaters:
•
Vegetable oil
•
Biodiesel
2.
5
Switch box (fig. 5)
- 0: The pump is switched off
- 1: Low pump speed
- 2: High pump speed
A.Switch control
B Control light Low pump speed
C Control light High pump speed
D Pump regulator
E Connection cable
When the
pumpthermostat
is sufficiently pre-
heated, the fuel pump automatically starts up.
Summary of Contents for Bio Energy 1
Page 1: ...40 020 944 rev 05 2015...
Page 3: ...Bio Energy series 40 020 944 rev 05 2015 3 i 7 8 B A...
Page 66: ...66 40 020 944 rev 05 2015 Bio Energy series P 1 1 1 1 2 2 A B C D 1 3...
Page 67: ...Bio Energy series 40 020 944 rev 05 2015 67 p 1 4 2 2 1 20 C 2 2 2 150 900 450...
Page 71: ...Bio Energy series 40 020 944 rev 05 2015 71 p 5 2 1 2 3 4 X 4 G X X X X X X 7 1 5 0 06 X X 12...
Page 73: ...Bio Energy series 40 020 944 rev 05 2015 73 p 6 1 i 1 2 3 F 3 1 5...
Page 74: ...74 40 020 944 rev 05 2015 Bio Energy series P 4 50 C 5 3 6 1 5 7 8 9 4 D...
Page 75: ...Bio Energy series 40 020 944 rev 05 2015 75 p 10 11 5 1 7 12 13 3 Q 3 Q 14...