background image

Orion Star A222 and Star A322 Portable Conductivity Meters

North America 

166 Cummings Center 
Beverly, MA 01915  USA 
Toll Free: 1-800-225-1480 
Tel: 1-978-232-6000 
[email protected]

Netherlands

Tel: (31) 033-2463887 
[email protected]

India

 

Tel: (91) 22-4175-8800
wai.asia@thermofisher.com 

©2011 Thermo Fisher Scientific Inc. All rights reserved. All trademarks 
are the property of Thermo Fisher Scientific Inc. & its subsidiaries. 

Water Analysis Instruments

 

www.thermoscientific.com/water

China

Tel: (86) 21-68654588  
wai.asia@thermofisher.com

Singapore

 

Tel: (65) 6778-6876
wai.asia@thermofisher.com 

Japan

 

Tel: (81) 045-453-9175
wai.asia@thermofisher.com 

Australia

 

Tel: (613) 9757-4300
in Australia (1300) 735-296
InfoWaterAU@thermofisher.com

9 0 0 1 : 2 0 0 8

68X576602  RevA  0811

Viewing the Calibration Log

1.  In the measurement mode, press 

.

2. Press 

  or 

 to highlight 

View Log 

and press 

f3 (select)

.

3. Press 

 

or

 

 to highlight 

Calibration Log 

and press 

f2 (accept)

.

4. Press 

 

or

 

 to highlight 

Conductivity – Channel 

and press 

f2 (select)

.

5. Press 

 

or

 

 to highlight 

Conductivity, Resistivity, TDS, Salinity 

or 

Temperature 

as the calibration type 

and press

 f2 (select)

.

6.  The meter will display a list of calibrations for the selected channel and calibration type. The list shows the 

sequential number of the calibration and the date and time it was saved (

07/01/2011 12:45

).

7.  To view the calibration data, press 

 

or

 

 to highlight a specific calibration and press 

f2 (select)

Press 

f2 (print)

 to print the calibration or press 

f1 (back)

 to return to the list of calibrations.

8. Press 

 to return to the measurement mode. 

Viewing the Data Log

1.  In the measurement mode, press 

.

2. Press 

  or 

 to highlight 

View Log 

and press 

f3 (select)

.

3. Press 

 

or

 

 

to highlight 

Data Log 

and press

 

(accept)

.

4.  The meter will display a list of the data points. The list shows the sequential number of the data point and 

the date and time the data point was saved (

07/01/2011 12:45

).

5.  To view the measurement information for an individual data point, press 

 

or

 

 to highlight the data point 

and press 

f2 (select)

. Press 

f2 (print)

 

to print the data point or press 

f1 (back)

 to return to the list of data points.

6. Press 

 to return to the measurement mode.

Summary of Contents for Star A222

Page 1: ...top portion of the battery cover from the meter use a coin or your nger and release the bottom portion of the battery cover d Orientate the batteries as shown in the battery compartment housing and i...

Page 2: ...ion was successfully completed M 100 Indicates a method is in use and the number of the method being used Cond Indicates the type of measurement and determines the type of calibration that will be per...

Page 3: ...lay Press to turn the meter on When the meter is on press and quickly release to turn the display backlight on or off or hold down to turn the meter off In the measurement mode press to take a measure...

Page 4: ...the conductivity cell and standard are ready press f3 start 4 Wait for the conductivity value on the meter to stabilize and stop ashing and perform one of the following actions a Press f2 accept to ac...

Page 5: ...and record the conductivity TDS salinity or resistivity and temperature of the sample c Star A322 meter only If the meter is in timed mode the meter will log measurements at the preselected time inte...

Page 6: ...ric entry screen will popup on the display ii Press or to highlight a number decimal place or negative sign press f3 enter to select the highlighted item and repeat until the desired value is shown on...

Page 7: ...ted at by the meter if temperature compensation is enabled 1 In the measurement mode press 2 Press or to highlight COND Channel and press f3 select 3 Press or to highlight Mode and Settings and press...

Page 8: ...t Conductivity Channel and press f2 select 5 Press or tohighlightConductivity Resistivity TDS SalinityorTemperatureasthecalibrationtype andpressf2 select 6 The meter will display a list of calibration...