background image

User Manual

Compact Digital Rocker
Compact Digital Waving Rotator

Operation Manual 9240-11-016

Summary of Contents for Compact Digital Rocker

Page 1: ...User Manual Compact Digital Rocker Compact Digital Waving Rotator Operation Manual 9240 11 016 ...

Page 2: ...eserves the right to change information such as specifications appearance and dimensions described in this document without notice Thermo makes no representations or warranties with respect to this manual In no event shall Thermo be held liable for any damages direct or incidental arising out of or related to the use of this manual No part of this manual may be reproduced or transmitted in any for...

Page 3: ... your instrument 2 These alerts are classified into four types in this manual depending on the importance and the risk levels as described below 3 The claim which is out of the quality guarantee published by the Manufacturer is out of Manufacturer s responsibility 4 The damage which is from unexpected fault or damage of user by Acts of God is out of Manufacturer s responsibility Symbols Meaning In...

Page 4: ...n fill your needs for spare or replacement parts or provide you with on site service We can also provide you with a quotation on our Extended Warranty for your Thermo Scientific products Whatever Thermo Scientific products you need or use we will be happy to discuss your applications If you are experiencing technical problems working together we will help you locate the problem and chances are cor...

Page 5: ...3 2 Tray Installation 3 2 Connecting to the Mains Power Supply 3 2 Operation 4 1 Start and Stop 4 2 How to Set the Timer 4 2 Stop Timer Mode 4 3 How to Adjust Shaker Angle 4 4 Maintenance 5 1 Cleaning of Tray and Unit Body 5 1 Keeping Product 5 1 Troubleshooting 6 1 Error Message on DIsplay 6 3 Accessories 7 1 Technical Specifications 8 1 Warranty Information 9 1 Section 1 Section 2 Section 3 Sect...

Page 6: ...sther Nitro compound Inflammable materials salt peroxides inorganic peroxide salt acids Check equipment for permissible environmental conditions when used inside Temp Humid Chamber or Incubator It can be cause of fire or trouble by shaker electricity electronic and damage of motor Shaker Permissible environmental condition Temperature 2 C to 60 C Maximum relative humidity 80 Wear your personal pro...

Page 7: ...s SCR controller Do not inject any liquid and inflammable things inside of product Do not pure water or put liquid on the top of the product when cleaning Intercept the main power immediately and request the service when water may be in the product Do not let the product take any strong shock or vibration It causes abnormal operation or trouble It may deteriorate the ability of the product and not...

Page 8: ...ker 5 100 rpm Compact Digital Waving Rotator 8 100 rpm for their own purposes 4 The controller display uses VFD Vacuum Fluorescent Display It is easy to indicate stirrer set up and operating condition 5 Operator friendly tilt angle can be set for their own purpose tests Compact Digital Rocker Tilt 7 13 adjustable Compact Digital Waving Rotator Tilt 0 13 adjustable 6 If the angle is set at 0 on wav...

Page 9: ...fix and tie the sample See Accessories section 4 VFD panel Controller The panel indicates product setting and control condition 5 Touch Button to choose RPM or TIMER individually operating by orange and green LED lamp 6 Dial Knob to set a shaking speed timer and start stop 7 Power switch the main ON OFF switch and supplying power of the product Waving Rotator back Rocker back 8 Foot to prevent fro...

Page 10: ...ervice Department Temperature 2 C 60 C Relative Humidity RH 10 80 Maximum Altitude Up to 2000m The unit should be located away from naked flame sources direct sunlight It can cause a malfunction or lower the function Place the unit onto a table as far as possible when in use and keep suitable distance from other instruments Do not place the unit near other laboratory equipment which can be readily...

Page 11: ... the protrusions of tray into the 4 holes of main body STEP 2 Check if the tray is fitted perfectly Connect the electric power to the unit according to the following process STEP 1 Switch off the main switch before connecting AC power cable STEP 2 Connect the power cable to the socket located on the unit back Use only the power cord supplied with unit Tray Installation Rubber band Silicone pad or ...

Page 12: ...ode PV Current RPM SV Setting RPM Run It indicates the unit works Stop It indicates the unit stops Rem n It shows remaining time during Timer mode operation 2 RPM button It indicates that the unit works RPM can be verified during Timer mode operation Compact Digital Rocker Compact Digital Waving Rotator 3 TIME button Timer and Run time can be verified 4 Dial knob RPM setting Input time or stop the...

Page 13: ...1 Press button when the unit stops 2 Time input display shows when you press the dial knob Input Hour Min Hour blinks during setting STEP 1 Input hour by rotating dial knob to right or left direction STEP 2 Press dial knob 1 time STEP 3 Input minute by rotating dial knob to right or left direction STEP 4 Press dial knob 1 time Display moves to next mode RPM setting 4 2 Magnetic Stirrer Thermo Scie...

Page 14: ...atus Timer function can stop as follows STEP 1 Press the dial knob STEP 2 Choose STOP YES by rotating the dial knob to the clockwise STEP 3 Press the dial knob Stop button does not work during timer function Please read carefully Stop Timer Mode section before using timer function RPM can be set from 5 rpm If Timer button is pressed during timer setting the unit returns to Stand by display Time an...

Page 15: ... screw to set desired angle STEP 3 Rotate the screw to anti clockwise to fix the angle Compact Digital Waving Rotator STEP 1 Lift up the tray with your hands STEP 2 Rotate the screw at the center with screwdriver or coin to set the desired angle 4 4 Magnetic Stirrer Thermo Scientific Section 4 Operation How to Adjust Shaker Angle Á À Î À Angle adjustment part Angle adjustment part ...

Page 16: ...ent from the main power 2 Clean the instrument with a soft cloth neatly 3 Store in a dry place after packing Classification Inspection cycle Daily Weekly General Power cord Inspect power cord connection at unit and receptacle Inspect power cord for wear cracks or cuts Cleanness for the surface of the unit Body unit Controller display checking Controller function Motor on off checking Attachment co...

Page 17: ...e might be cut If the socket plug main power line are cut request service Reagents spill into the unit and break the circuit inside the unit Request service Room circuit breaker trips often when the unit is turned on or running Too many plugs connect at the same time 1 Check the circuit breaker size along with the voltage and current supplied to it 2 Check that several similar units are inserted t...

Page 18: ...sure it is fully seated If the socket plug main power line are cut request service PCB is damaged by reagent Request service Room circuit breaker trips often when the unit is turned on or running Too many plugs connect at the same time 1 Check the circuit breaker size along with the voltage and current supplied to it 2 Check that several similar units are inserted together if so you should not use...

Page 19: ...range of uses Motor driver board problem Request service Average life of motor ends Request service WARN KEY In the key of button pressed Request service in case symptoms remain MOTR CHEK Motor driver board problem communication part Request service Bad wiring connection between the motor driver and motherboard Request service If buzzer rings with no display Sub CPU problem Request service ...

Page 20: ...er Mat Tray 88880101 276 X 276 10 84 X 10 84 Sticky pad 250 X 250 9 84 X 9 84 Dimpled Mat Tray 88880102 276 X 276 10 84 X 10 84 Silicone pad 250 X 250 9 84 X 9 84 Universal Harness Tray 88880103 276 X 276 10 84 X 10 84 Sticky pad 250 X 250 9 84 X 9 84 Rubber bands 6ea Rubber bands Rubber band 88880105 ...

Page 21: ...D Display VFD Shaking system Motion type Rocking type Waving type Speed range rpm 5 100 8 100 Speed accuracy at 100 rpm 5 rpm Adjustable tilt 7 13 0 13 Max load kg lbs 5 11 02 Dimension Tray W X D mm inch 276 X 276 10 87 X 10 87 Overall W X D X H mm inch 276 X 320 X 150 10 87 X 12 6 X 5 91 Net weight kg Ibs 3 7 8 16 Materials Main body PP Polypropylene Dimpled mat PP Polypropylene Silicone Electri...

Page 22: ...ot covered by this warranty agreement The Technical Services Department must be contact ed for warranty determination and direction prior to performance of any repairs Expendable items glass filters and gaskets are excluded from this warranty Replacement or repair of components parts or equipment under this warranty shall not extend the warranty to either the equipment or to the compo nent part be...

Page 23: ...Thermo Fisher Scientific 401 Millcreek Road Marietta Ohio 45750 United States www thermofisher com ...