v
If you transfer the Software Program, you must transfer a copy of these License Terms, all other
documentation and at least one complete, unaltered copy of the Software Program to the other party.
Unless you have other copies of the Software Program to be used in connection with other
Equipment purchased from
Thermo
, or one of its divisions, you must, at the same time, either
transfer all your other copies of the Software Program to the transferee of the Equipment or destroy
them. Your license is then terminated. The other party agrees to these terms and conditions by its
first use of the Software Program.
You must reproduce the copyright notices(s) on each copy of the Software Program.
You may not:
1.
Use, copy, modify, merge, or transfer copies of the Software Program except as provided in this
license;
2.
Reverse engineer, decompile, or disassemble the Software Program; or
3.
Sub-license, rent, lease, or assign the Software Program.
Limitation of Remedies
Thermo Fisher Scientific
entire liability under this license is the following:
Thermo Fisher Scientific
will: (a) replace defective media, or (b) make a warranted Software
Program operate or (c) replace the Software Program with a functionally equivalent Software
Program, as warranted.
For any claim (including breach), in any form, related in any way to this license,
Thermo Fisher
Scientific
s liability will be for the actual value of the Software Program.
Thermo Fisher Scientific
will not be liable for any lost profits, lost savings, any incidental damages,
or other economic consequential damages, even if
Thermo
, or its authorized supplier, has been
advised of the possibility of such damages.
Thermo Fisher Scientific
will not be liable for any
damages claimed by you based on any third party claim.
General
Thermo Fisher Scientific
may terminate your license if you fail to comply with the terms and
conditions of this license. In such event, you must destroy all your copies of the Software Program.
You are responsible for payment of any taxes, including personal property taxes, resulting from this
license.
Occupational Safety and Health Act (OSHA)
The Occupational Safety and Health Act clearly places the burden of compliance on the user of the
equipment and the act is generalized to the extent that determination of compliance is a judgment
decision on the part of the local inspection. Hence,
Thermo Fisher Scientific
will not be responsible
for meeting the full requirements of OSHA in respect to the equipment supplied or for any penalty
assessed for failure to meet the requirements, in respect to the equipment
supplied, of the
Occupational Safety and Health Act, as interpreted by an authorized inspector.
Thermo Fisher
Scientific
will use their best efforts to remedy such violation at a reasonable cost to the buyer.
Summary of Contents for 20-35-NM-DIN
Page 2: ...ii ...
Page 6: ...vi ...
Page 11: ...xi ...
Page 18: ...xviii PROBE Models 20 54 NM SS 20 52 NM 20 59 NM 20 55 NM P TAG MARKING CE Certification CE ...
Page 24: ...1 6 ...
Page 28: ...2 4 Figure 2 3 Probe Model 20 54 NM SS Stainless Steel Probe Dimensions are inches and mm ...
Page 29: ...2 5 Figure 2 4 Probe Model 20 52 NM Heavy Weight Probe Dimensions are inches and mm ...
Page 30: ...2 6 Figure 2 5 Probe Model 20 59 NM Steel Probe Dimensions are inches and mm ...
Page 31: ...2 7 Figure 2 6 Probe Model 20 55 NM P Plastic Probe Dimensions are inches and mm ...
Page 33: ...2 9 Figure 2 8 Control Unit Model 20 35 NM F Internal Layout ...
Page 35: ...2 11 Figure 2 10 Control Unit Model 20 35 NM DIN Internal Layout FAULT ...
Page 36: ......
Page 38: ...3 2 Low Application Examples Typical Plugged Transfer Chute Alarms ...