background image

S

PEEDVAC

®

CONCENTRATOR 

SPD-SERIES BASIC 

SPD101B

INSTRUCTION MANUAL

A Thermo Electron business

Summary of Contents for SPEEDVAC SPD Series

Page 1: ...SPEEDVAC CONCENTRATOR SPD SERIES BASIC SPD101B INSTRUCTION MANUAL A Thermo Electron business...

Page 2: ...red Table of Contents Section Section Title Overview Page 1 0 Overview of the SPD101B Unit 1 1 1 Installation of the SPD101B Unit 2 1 2 How to Hook Up the SPD101B Unit 2 Section Section Title Control...

Page 3: ...on 6 Right Side Panel 7 Chamber View Window 8 Vacuum Port 9 AC Socket 10 Main On Off Switch 11 Manual Cover Lock Release 12 Rear Access Panel 1 2 3 4 5 6 12 8 9 10 11 7 Figure 1 Front View Figure 2 Si...

Page 4: ...9 Fax 631 244 0606 3 If the unit is part of a larger system use vacuum tubing supplied to hook up unit See figure 4 4 Vacuum clamps must be put on vacuum ports of pump and SPD unit See item 8 on figur...

Page 5: ...view the preset parameters during the run 4 TEMPERATURE DISPLAY GREEN DISPLAY Indicates set temperature or actual temperature during pre heat or during a run from 45 C to 80 C or NO heat 5 RUN TIME D...

Page 6: ...p cover to be opened RED power light is ON The display lights up showing the default values TEMPERATURE 45 C GREEN TIME 0 00 HRS GREEN 3 Place sample tubes in rotor so load is balanced Secure rotor wi...

Page 7: ...ials 20 x 47mm v vials 1 dram vials 15 x 45mm 4ml 20 x 60mm v vials 18 x 52mm mini scintillation vials 28 x 60mm scintillation vials Microplates Deepwell Microplates 40 64 120 100 40 100 20 40 72 10 3...

Page 8: ...choice please contact the Applications Support Specialists at Thermo Savant at 1 800 634 8886 or 631 244 2929 or Fax 631 244 0606 Part I Solvents suited for the SPD101B unit Ethanol Methanol Water Ace...

Page 9: ...bsorbent towels Always wear gloves when cleaning and dispose of paper towel in appropriate designated refuse containers 3 Replace chamber seal if cracked Part number is 197 6020 00 4 Outside of unit c...

Page 10: ...equential damages Warranty work is subject to our inspection of the unit No instruments equipment or accessories will be accepted without a Return Material Authorization RMA number issued by Thermo Sa...

Page 11: ...YSTEM SpeedVac Concentrator SPD101B UVS400 Universal Vacuum Source ANT100 BV130 Bleeder Valve Vacuum Tubing COMPONENT HIGH VACUUM SYSTEM BV130 Bleeder Valve Flexible Vacuum Tubing DVG50 SpeedVac Conce...

Page 12: ...SPD SERIES SPEEDVAC FAMILY SPD101B SPD111V SPD121P...

Page 13: ......

Page 14: ...97 3000 00 Rev B 2000 Thermo Savant 100 Colin Drive Holbrook NY 11741 4306 USA Tel 631 244 2929 1 800 634 8886 Fax 631 244 0606 www thermosavant com E mail savantec savec com A Thermo Electron busines...