13
5. BASIC OPERATIONS
NOTE 3: In case the user wants to STOP the printout (i.e. because of
wrong ticket selection), it is possible to do so by pressing the Down
arrow key. Then the user will be prompted with a choice asking to
confirm the need to STOP the printout.
NOTE 4: With the TDP enabled, the oldest log of the selected time
period is printed first, the latest log is printed last for the journey
tickets.
Oldest Data
See Note 6
Newest Data
Sample Ticket
NOTE 5: It is always recommended to enable automatic SOT (refer
section "10.1 Appendix 1"on page 25 for more information) in
CargoWatch to prevent creating long trips. This will prevent long
waiting time for TDP enabled journey tickets.
NOTE 6: The START and FINISH are determined by the latest trip
information, and not by the duration of the ticket requested.
5.4 PRINT MENU PRINT BY DATE OPTION
DISABLED
In that case, the user has as well 2 format options to print, but they work
in a slightly different way.
i
5.4.1 DELIVERY TICKET
Same as when the Temporary Data park is enabled, this function allows
to print the last received temperature measurements alongside the Set
Point with a date and time stamp on the ticket. The trailer ID,
the Datalogger details (model, serial number) and the controller details
(version, type, serial number) are also included in the ticket header, as
well as the sensors labels.
5.4.2 JOURNEY TICKET TABULAR
With the Temporary Data park disabled (Print by Date OFF), there is only
1 option available for the journey ticket. This function allows to print
the last identified journey information recorded in the datalogger based
on the marker (Start of Trip).
NOTE 1: With the TDP disabled, the latest log of the selected trip is
printed first, the oldest log is printed last for the journey tickets.