![background image](http://html1.mh-extra.com/html/thermo-king/thermolite-401414/thermolite-401414_installation-instructions-manual_1104423006.webp)
6
©2020 Trane Technologies
TK 56579-11-IS-EN (Rev. A, 10/20)
4. Attach positive (white/red) wire to the positive terminal on the starter solenoid (terminal with
the battery cable attached).
5. Secure the fuse holder to the existing harness.
Figure 7.
Positive wire and fuse holder shown.
RCS1504
6. Attach negative (black) wire with terminal ring to engine block ground stud behind oil filter.
N
No
otte
e:: The black wire with terminal ring should be installed under the flat washer followed by
the large ground cable and the external lock washer last.
Figure 8. Negative wire shown attached to engine block.