The SPECTRUM™ multi-temperature
refrigeration system provides heavy duty
temperature control for multiple compartment
trucks. The system provides direct expansion
cooling in all cargo compartments.
Heat and defrost is provided in all compartments
by circulating hot refrigerant gas through the
evaporators.
The remote evaporator are ceiling mounted units.
Controls for the remote evaporator(s) are located
in the SPECTRUM
™
TS HMI.
Unit Operation
The remote evaporator cycles between cool, null
and heat to maintain the cargo’s compartment(s)
at the setpoint. The operating modes include Cool,
Null, Heat and Defrost.
Power to run the direct current fan motor is
supplied by the alternator in the condensing unit.
When cooling is required, the SPECTRUM™ TS
microprocessor energizes the remote liquid line
solenoid valve. Refrigerant flows through the
evaporator coil to provide cooling.
When the compartment temperature is near
setpoint, the SPECTRUM™ TS microprocessor
de-energizes the remote liquid line solenoid valve
and switches the remote evaporator to null.
The SPECTRUM™ TS microprocessor energizes
the remote hot gas solenoid when the remote
compartment requires heat or defrost.
Defrost
The Defrost mode can be initiated any time the
evaporator coil temperature is below 45 F (7 C).
Defrost is initiated automatically by the controller
or manually by selecting the manual defrost.
The evaporator fan stops during defrost. The
Defrost mode will continue until the evaporator
coil temperature rises to 52 F (11 C), causing the
controller to terminate defrost. After defrost, the
evaporator may shift back to cool, null or heat.
Operating Modes
Remote evaporator operating modes are:
•
Cool
•
Null
•
Heat
•
Defrost
NOTE: The controller locks out heat at setpoints
below 15 F (-9.5 C).
Unit Features
•
Direct Expansion Evaporator Coil
•
SPECTRUM
™
TS Microprocessor
•
12 Vdc Fan Motor
•
Aluminum Housing
•
Liquid Line Solenoid
•
Hot Gas Solenoid
•
Suction Line Solenoid
•
Liquid Return Check Valve
Summary of Contents for SPECTRUM TS 30 SR NAD
Page 4: ...4 ...
Page 10: ...Table of Contents 10 ...
Page 20: ...Safety Precautions 20 ...
Page 51: ...Unit Description 51 Figure 19 Front View Figure 20 Back View AJA1350 AJA1500 ...
Page 52: ...Unit Description 52 1 On Off Switch Figure 21 Side View 1 ...
Page 60: ...Unit Description 60 ...
Page 80: ...SPECTRUM TS Operation 80 ...
Page 90: ...Electrical Maintenance 90 ...
Page 100: ...Engine Maintenance 100 Figure 130 Early TK 3 95 Fuel and Oil System Components ...
Page 102: ...Engine Maintenance 102 Figure 131 Late TK 3 95 Fuel and Oil System Components ...
Page 104: ...Engine Maintenance 104 Figure 132 TK376 Fuel and Oil System Components ...
Page 136: ...Refrigeration Maintenance 136 ...
Page 156: ...Hilliard Clutch Maintenance 156 ...
Page 158: ...Structural Maintenance 158 ...
Page 168: ...Remote Evaporator Specifications 168 ...
Page 170: ...Remote Evaporator Maintenance Inspection Schedule 170 ...
Page 176: ...Remote Evaporator Electrical Maintenance 176 ...
Page 180: ...Remote Evaporator Refrigeration Service Operations 180 ...
Page 182: ...Remote Evaporator Structural Maintenance 182 ...
Page 184: ...Remote Evaporator System Diagnosis 184 ...
Page 188: ...Wiring and Schematic Diagrams Index 188 ...
Page 189: ...189 Wiring Diagram Page 1 of 4 ...
Page 190: ...190 Wiring Diagram Page 2 of 4 ...
Page 191: ...191 Wiring Diagram Page 3 of 4 ...
Page 192: ...192 Wiring Diagram Page 4 of 4 ...
Page 193: ...193 Schematic Diagram Page 1 of 3 ...
Page 194: ...194 Schematic Diagram Page 2 of 3 ...
Page 195: ...195 Schematic Diagram Page 3 of 3 ...
Page 196: ...196 ...