157
Structural Maintenance
Unit and Engine Mounting Bolts
Periodically check and tighten all unit and engine
mounting bolts. Torque the unit mounting
bolts to 60 ft-lb (81.3 N•m). Torque the engine
mounting bolts to 50 ft-lb (68 N•m).
Figure 182: Mounting Bolts
Unit Inspection
Inspect the unit during unit pretrip inspection and
scheduled maintenance inspections for loose or
broken wires or hardware, compressor oil leaks,
or other physical damage which might affect unit
performance and require repair or replacement of
parts.
Condenser and Radiator Coils
Clean the coils during scheduled maintenance
inspections. Remove any debris (e.g., leaves or
plastic wrap) that reduces the air flow. Clean dirty
coils with compressed air or a pressure washer. Be
careful not to bend the fins when cleaning a coil.
If possible, blow the air or water through the coil
in the direction opposite the normal air flow.
Repair bent fins and any other noticeable damage.
Fan Location
When mounting the fan and hub assembly on the
fanshaft, position the assembly in the orifice as
follows for proper fan performance:
•
For all fans except the ten-blade condenser
fan, position the fan with 30 to 35 percent of
the blade width to the air discharge side.
•
For the ten-blade condenser fan, position the
fan with 50 percent of the blade width to the
air discharge side.
Figure 183: Fan Blade Position in Orifice
for All Except Ten-Blade Fan
Figure 184: Fan Blade Position in Orifice
for Ten-Blade Fan
CAUTION: Air pressure should not be
high enough to damage coil fins.
ORIFICE
AIR
FLOW
50 Percent
of Blade Depth to
Air Discharge Side
Summary of Contents for SPECTRUM TS 30 SR NAD
Page 4: ...4 ...
Page 10: ...Table of Contents 10 ...
Page 20: ...Safety Precautions 20 ...
Page 51: ...Unit Description 51 Figure 19 Front View Figure 20 Back View AJA1350 AJA1500 ...
Page 52: ...Unit Description 52 1 On Off Switch Figure 21 Side View 1 ...
Page 60: ...Unit Description 60 ...
Page 80: ...SPECTRUM TS Operation 80 ...
Page 90: ...Electrical Maintenance 90 ...
Page 100: ...Engine Maintenance 100 Figure 130 Early TK 3 95 Fuel and Oil System Components ...
Page 102: ...Engine Maintenance 102 Figure 131 Late TK 3 95 Fuel and Oil System Components ...
Page 104: ...Engine Maintenance 104 Figure 132 TK376 Fuel and Oil System Components ...
Page 136: ...Refrigeration Maintenance 136 ...
Page 156: ...Hilliard Clutch Maintenance 156 ...
Page 158: ...Structural Maintenance 158 ...
Page 168: ...Remote Evaporator Specifications 168 ...
Page 170: ...Remote Evaporator Maintenance Inspection Schedule 170 ...
Page 176: ...Remote Evaporator Electrical Maintenance 176 ...
Page 180: ...Remote Evaporator Refrigeration Service Operations 180 ...
Page 182: ...Remote Evaporator Structural Maintenance 182 ...
Page 184: ...Remote Evaporator System Diagnosis 184 ...
Page 188: ...Wiring and Schematic Diagrams Index 188 ...
Page 189: ...189 Wiring Diagram Page 1 of 4 ...
Page 190: ...190 Wiring Diagram Page 2 of 4 ...
Page 191: ...191 Wiring Diagram Page 3 of 4 ...
Page 192: ...192 Wiring Diagram Page 4 of 4 ...
Page 193: ...193 Schematic Diagram Page 1 of 3 ...
Page 194: ...194 Schematic Diagram Page 2 of 3 ...
Page 195: ...195 Schematic Diagram Page 3 of 3 ...
Page 196: ...196 ...