20
Installer/Serviceman Labels
INSTALLER/SERVICEMAN
Model Number
TDX-WC 90 TDX-WC 100 TDX-WC 110
TDX-WC 125
Burner Type
Beckett
Beckett
Beckett
Burner Model
NX
NX
NX
Nozzle Type
0.70 60°B
0.75 60°B
0.85 60°B
N/A
Pump Pressure PSI
175
175
175
N/A
Head/Pin Position
2.5
3.00
4.5
N/A
Air Band
N/A
N/A
N/A
N/A
Air Shutter
N/A
N/A
N/A
N/A
Draft Over Fire
+0.06"
+0.08"
+0.10"
N/A
Draft In Stack
-0.02"
-0.02"
-0.02"
N/A
CO2 Reading
10-12%
10-12%
10-12%
N/A
Smoke Reading
ZERO
ZERO
ZERO
N/A
NOTICE
Above settings are approximate. Final adjustments to be made
with proper test equipment. Be sure all oil lines are air free and
the use of flare fittings is recommended. See installation/ser-
vice manual for detailed information.
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
INSTALLER/SERVICEMAN
Model Number
TDX-WC 90 TDX-WC 100 TDX-WC 110
TDX-WC 125
DV
DV
DV
DV
Burner Type
Beckett*
Beckett*
Beckett*
Burner Model
NX
NX
NX
Nozzle Type
0.70 60°B
0.75 60°B
0.85 60°B
N/A
Pump Pressure PSI
175
175
175
N/A
Head/Pin Position
2.75
3.25
4.00
N/A
Air Band
N/A
N/A
N/A
N/A
Air Shutter
N/A
N/A
N/A
N/A
Draft Over Fire
+0.080"
+0.115"
+0.125"
N/A
Draft In Stack
+0.040"
+0.055"
+0.065"
N/A
CO2 Reading
10-12%
10-12%
10-12%
N/A
Smoke Reading
ZERO
ZERO
ZERO
N/A
*Beckett Air Boot Adaptor
NOTICE
Above settings are approximate. Final adjustments to be made
with proper test equipment. Be sure all oil lines are air free and
the use of flare fittings is recommended. See installation/ser-
vice manual for detailed information.
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
_____________________________
Appendix E
See the label attached to your boiler for data specific to your boiler.
N/A
N/A