background image

2

2

ENGLISH

 

 

Dear Customer,

Thank you for preferring a 

T

 heating unit, a mod-

ern, high-quality product that is able to guarantee your maxi-

mum well-being for a long period of time, with high levels of 

reliability and safety. In particular, if working together with a 

Technical Assistance Centre 

T

 that is specifically 

prepared and trained to perform periodic maintenance, your 

unit will remain at maximum efficiency levels at minimum op-

erating costs and if required, replacements with original spare 

parts can be made.

This instruction manual contains important instructions and 

precautions that must be observed to ensure the trouble-free 

installation and efficient functioning of your 

ACQUAHOME I BLU

 

boiler.

Please accept our renewed thanks for your purchase

Thermital

CONFORMITY

ACQUAHOME I BLU

 boilers conform to the following directives:

- Directive 92/42/EEC on efficiency requirements

- Electromagnetic Compatibility Directive 2014/30/EU

- Low Voltage Directive 2014/35/EU

- Ecodesign Directive 2009/125/CE for energy-related 

products

- Regulation (EU) 2017/1369 Energy labelling

- Delegated Regulation (EU) N. 811/2013

- Delegated Regulation (EU) N. 813/2013

- Delegated Regulation (EU) N. 814/2013

At the end of its life, the product should 
be not be disposed of as solid urban 
waste, but rather it should be handed over 
to a differentiated waste collection centre.

ENGLISH

Summary of Contents for ACQUAHOME I BLU

Page 1: ...ACQUAHOME I BLU USER MANUAL...

Page 2: ...recautions that must be observed to ensure the trouble free installation and efficient functioning of your ACQUAHOME I BLU boiler Please accept our renewed thanks for your purchase Thermital CONFORMIT...

Page 3: ...ety and control devices 5 System layout 6 Control panel 7 Menu navigation 9 Navigation scheme 11 List of user parameters 12 USE 14 Putting into service 14 Preliminary operations 14 Start up 14 Adjustm...

Page 4: ...for an extended peri od of time perform the operations described later in this manual b This manual is an integral part of the equipment and therefore must be stored carefully and must ALWAYS ac compa...

Page 5: ...or which views and continually checks the primary circuit pressure to switch on the generator or cause it to stop in case of low pressure Boiler temperature probes delivery and return immer sion probe...

Page 6: ...c actuator 3 Safety valve 4 Main switch 5 Domestic plate exchanger 6 Control panel 7 System load valve 8 Heating expansion reservoir 9 Burner 10 Boiler drain cock 11 Pump 12 Flame inspection window 13...

Page 7: ...g the operation after a stop due to an anomaly 5 Navigation keys 6 Main switch located on the equipment rear wall Light Guide displaying STATUS DESCRIPTION Green blinking Thermal unit drain cycle and...

Page 8: ...e Installer menu 4 Icon displayed when the burner of the equipment is on The icon will be marked with a cross in case of Permanent or Temporary error 5 Icon displayed when the climatic mode operation...

Page 9: ...setpoint when active available 3 Raise the DHW set point when available 4 Decrease the DHW set point when available 5 ENTER RESET Enters into MENU mode If pressed for more than 5 seconds it resets a p...

Page 10: ...de keys have the following functions Nr Button Function 1 Exits from the menu and cancels a parameter change 2 Exits from the menu and cancels a parameter change 3 Selects the following menu or increa...

Page 11: ...11 11 ENGLISH Navigation scheme Modalit visualizzazione base Modalit utente Bar C oppure Example of parameter setting change confirmed change canceled or or or...

Page 12: ...operation 0 1 0 Info menu 1000 1001 CH flow temperature C 1000 1002 Domestic hot water temperature C 1000 1003 Domestic cold water temperature This parameter is only visible with Par 2035 10 C 1000 10...

Page 13: ...the setpoint BT Par 2221 45 AT Par 2221 Par 2024 70 AT 45 BT C 2000 2230 Parallel shift of direct Zone Zone 1 climatic curve 10 10 0 C Zone 3 Heating Settings 2000 2303 Zone 3 heating setpoint in 0 an...

Page 14: ...the thermal unit Bar C close the system load valve Start up Once you have completed all the checks listed above pro ceed as follows to start up the boiler for the first time set the main switch of th...

Page 15: ...e of the heating temperature setpoint C Increase or decrease the setpoint according to the type of system by using the key of To save the modification made and go back to the initial screen wait for 3...

Page 16: ...the first start up and at each reset of the power supply When the function is active the message Air is displayed During the venting the circulator is enabled so that the air which may be present ins...

Page 17: ...Please remember that THE PERSON RESPONSIBLE FOR SYSTEM MANAGEMENT MUST ENSURE THAT PROFES SIONALLY QUALIFIED HEATING ENGINEERS UNDERTAKE PERIODIC MAINTENANCE AND COMBUSTION EFFICIENCY MEASUREMENTS T...

Page 18: ...ature Contact your local Technical Assistan ce Centre No water Contact your local Technical Assistan ce Centre The safety valve keeps opening Incorrect central heating circuit pressure Contact your lo...

Page 19: ...cycle safely remove the components and dispose of them in a responsible manner in compliance with the installation country s applicable environmental legislation b Adequate sorted waste collection pr...

Page 20: ...lade Riello 7 37045 Legnago VR www thermital it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are ther...

Reviews: