thermital ACQUAHOME I BLU User Manual Download Page 5

5

5

ENGLISH

 

 

Description of the appliance

The thermal unit 

ACQUAHOME I BLU

 is a hot water generator for 

the heating of environments and instant production of domes-

tic hot water (DHW) by means of a dedicate plate exchanger.

It can function at low temperature and is oil fuelled.

The low NOx burner features a single-stage operation and a 

vertical steel combustion chamber.

The boiler unit is effectively and accurately insulated with a 

high-density glass wool mat.

The control panel includes a user interface with display and an 

electronic board for the thermal unit adjustment and control, 

which allows to manage the control and safety devices in com-

pliance with the regulations in force.

Safety and control devices

The control panel, apart from managing the functions of the 

thermal unit 

ACQUAHOME I BLU

, allows to highlight any anom-

aly which may affect its correct operation, ensuring the thermal 

unit safety by stopping it and automatically closing the burner 

light oil valve.

The burner control and adjustment board is also used to en-

sure the burner safety by managing its correct operation.

Any anomaly which may affect the generator operation forces 

it to stop (lock-out) and is promptly signalled with a numerical 

error code on the regulator display.

The following are installed on the water circuit:

Safety thermostat

: fitted on the generator body, it inter-

venes by stopping (permanent error) the thermal unit 

if the boiler temperature exceeds the limit threshold of 

110°C;

Safety valve

: intervenes if the boiler pressure exceeds 

the limit threshold of 3 bar;

Pressure transducer

: sends a signal to the electron-

ic regulator which views and continually checks the 

primary circuit pressure to switch on the generator or 

cause it to stop in case of low pressure;

Boiler temperature probes (delivery and return)

: immer-

sion probe on the delivery line of the generator is used 

by the regulator to view and check the delivery water 

temperature and check the correct switching on and off 

of the burner based on the programmed setpoint. The 

regulator uses the same probe to switch off the genera-

tor in case of overtemperature, before the triggering of 

the safety thermostat. The contact probe placed on the 

return line of the boiler is used by the regulator to view 

the return water temperature with which it calculates, 

together with the delivery temperature, the temperature 

difference between delivery and return (

t), which al-

lows regulating the modulation of the circulator in heat-

ing mode.

Domestic circuit temperature probes (plate exchanger)

there are two temperature probes on the domestic plate 

exchanger circuit. One immersion probe is placed on 

the domestic cold water inlet and the other one on the 

domestic hot water outlet. The regulator uses these two 

probes to view and check the domestic water temper-

ature and manage the functions (DHW Setpoint, DHW 

request) of the relevant parameters.

The intervention of a safety device indicates a potentially 

dangerous malfunction in the system. Contact the manu-

facturer’s Technical Assistance Centre immediately.

Safety devices must only be replaced by the manufac-

turer's Technical Assistance Centre using original spare 

parts. Refer to the spare parts catalogue supplied with 

the boiler. After making the repair, check that the appli-

ance is working properly.

The appliance must not be put in service, even temporar-

ily, when tampered safety devices are not in operation or 

have been tampered with.

Summary of Contents for ACQUAHOME I BLU

Page 1: ...ACQUAHOME I BLU USER MANUAL...

Page 2: ...recautions that must be observed to ensure the trouble free installation and efficient functioning of your ACQUAHOME I BLU boiler Please accept our renewed thanks for your purchase Thermital CONFORMIT...

Page 3: ...ety and control devices 5 System layout 6 Control panel 7 Menu navigation 9 Navigation scheme 11 List of user parameters 12 USE 14 Putting into service 14 Preliminary operations 14 Start up 14 Adjustm...

Page 4: ...for an extended peri od of time perform the operations described later in this manual b This manual is an integral part of the equipment and therefore must be stored carefully and must ALWAYS ac compa...

Page 5: ...or which views and continually checks the primary circuit pressure to switch on the generator or cause it to stop in case of low pressure Boiler temperature probes delivery and return immer sion probe...

Page 6: ...c actuator 3 Safety valve 4 Main switch 5 Domestic plate exchanger 6 Control panel 7 System load valve 8 Heating expansion reservoir 9 Burner 10 Boiler drain cock 11 Pump 12 Flame inspection window 13...

Page 7: ...g the operation after a stop due to an anomaly 5 Navigation keys 6 Main switch located on the equipment rear wall Light Guide displaying STATUS DESCRIPTION Green blinking Thermal unit drain cycle and...

Page 8: ...e Installer menu 4 Icon displayed when the burner of the equipment is on The icon will be marked with a cross in case of Permanent or Temporary error 5 Icon displayed when the climatic mode operation...

Page 9: ...setpoint when active available 3 Raise the DHW set point when available 4 Decrease the DHW set point when available 5 ENTER RESET Enters into MENU mode If pressed for more than 5 seconds it resets a p...

Page 10: ...de keys have the following functions Nr Button Function 1 Exits from the menu and cancels a parameter change 2 Exits from the menu and cancels a parameter change 3 Selects the following menu or increa...

Page 11: ...11 11 ENGLISH Navigation scheme Modalit visualizzazione base Modalit utente Bar C oppure Example of parameter setting change confirmed change canceled or or or...

Page 12: ...operation 0 1 0 Info menu 1000 1001 CH flow temperature C 1000 1002 Domestic hot water temperature C 1000 1003 Domestic cold water temperature This parameter is only visible with Par 2035 10 C 1000 10...

Page 13: ...the setpoint BT Par 2221 45 AT Par 2221 Par 2024 70 AT 45 BT C 2000 2230 Parallel shift of direct Zone Zone 1 climatic curve 10 10 0 C Zone 3 Heating Settings 2000 2303 Zone 3 heating setpoint in 0 an...

Page 14: ...the thermal unit Bar C close the system load valve Start up Once you have completed all the checks listed above pro ceed as follows to start up the boiler for the first time set the main switch of th...

Page 15: ...e of the heating temperature setpoint C Increase or decrease the setpoint according to the type of system by using the key of To save the modification made and go back to the initial screen wait for 3...

Page 16: ...the first start up and at each reset of the power supply When the function is active the message Air is displayed During the venting the circulator is enabled so that the air which may be present ins...

Page 17: ...Please remember that THE PERSON RESPONSIBLE FOR SYSTEM MANAGEMENT MUST ENSURE THAT PROFES SIONALLY QUALIFIED HEATING ENGINEERS UNDERTAKE PERIODIC MAINTENANCE AND COMBUSTION EFFICIENCY MEASUREMENTS T...

Page 18: ...ature Contact your local Technical Assistan ce Centre No water Contact your local Technical Assistan ce Centre The safety valve keeps opening Incorrect central heating circuit pressure Contact your lo...

Page 19: ...cycle safely remove the components and dispose of them in a responsible manner in compliance with the installation country s applicable environmental legislation b Adequate sorted waste collection pr...

Page 20: ...lade Riello 7 37045 Legnago VR www thermital it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are ther...

Reviews: