18
ENGLISH
Water connections
The following table gives the dimensions and positions of the
water fittings for
ACQUAHOME 32 B - 32 BS
boilers.
Before installing the boiler, flush out all the pipes of the central
heating circuit to remove any machining residues.
MI
RI
UACS
RC
EAFS
SC
G
A
B
C
D
E
F
DESCRIPTION
ACQUAHOME
32 B - 32 BS
A
80
mm
B
120
mm
C
210
mm
D
460
mm
E
1020
mm
F
1080
mm
G
45
mm
MI (CH flow)
1” M
Ø
RI (CH return)
1” M
Ø
UACS (domestic hot water outlet)
1/2" M
Ø
RC (recirculation)
1/2" M
Ø
SC (drain)
10
mm
EAFS (domestic cold water inlet)
1/2" M
Ø
Boiler water circuit
CENTRAL HEATING RETURN
CENTRAL HEATING FLOW
DHW outlet
DHW circulation
Domestic cold water inlet
8
10
8
9
7
7
5
5
6
4
3
2
1
1 Boiler body
2 Automatic vent valve
3 Non-return valves
4 Pumps
5 Expansion vessel
6 Burner
7 Safety valve
8 Drain cock
9 Storage cylinder
10 Filling cock
Summary of Contents for 20109806