5.5
Hot water
The hot water settings are set from factory (or by installer for any installation specific requirements) for high
hot water comfort & availability with high savings efficiency. Therefore no adjustments are required. Automatic
top up (anti-legionella) is with factory setting performed in a one week interval in operating mode Auto.
For special occasions, when maximum availability of hot water is desired, a one-time top up heating "EXTRA
HOT WATER" may be initiated.
To activate, press > select "HOT WATER" and then "EXTRA HOT WATER".
If the operation mode "COMPRESSOR" is set when the function is activated, the top up will be done only on
compressor.
If operation mode Auto is set when the function is activated, both compressor & auxiliary heater will be used to
provide maximum amount of hot water.
Note! The function is only possible to activate when the hot water tank is not already considered as fully charg-
ed by the controller.
5.6
System information
Check applicable operating data described in the tables below. The information can be found in the sub-menu
INFORMATION > TEMPERATURE >
Operating data, temperature
Sensor
Explanation
Outdoor
Shows the temperature on the outdoor sensor.
System supply line
Optional. Depending on system application.
Desired supply line
Shows the calculated requirement value for the supply line.
Hot water
Shows the temperature of the hot water sensor, if hot water production is
permitted.
Supply line (HP)
Shows temperature of outgoing radiator temperature from heat pump.
Return line (HP)
Shows temperature of incoming radiator temperature to heat pump.
Brine in
Shows the current temperature of brine in to the heat pump.
Brine out
Shows the current temperature of brine out from the heat pump.
Operating time
The information can be found in the sub-menu INFORMATION > OPERAT.TIME >
Explanation
COMPRESSOR
Shows the number of hours that the heat pump has been in operation.
AUX. HEAT 1
Shows the number of hours that the immersion heater step 1 has been in
operation.
User Guide
Thermia Legend
Thermia AB
BWLE01UG0102
15