background image

Now you will need to decide on the steamhead placement in the shower so you can run the steam line from the generator to the 
steamhead. There are a couple of things you need to know about the placement of the steamhead and steam line itself.

24"

6"

B

7

 

Steam Line and Steamhead

A

C

Steam Line

Shown installed 

in attic  

DO NOT

 install any valve in the steam line. Flow of steam must 

be unobstructed.

DO NOT 

plumb any traps in the steam line.

The steam outlet on the generator requires a 1/2" brass   
union for easy installation (not included).

Use 1/2” brass pipe or copper tubing from unit to 

steamhead rough-in fitting as permitted by code.

A

B

The steam line can run up and then down, once; or horizontal; 
but never run down and then up. If it does, a steam trap will 

be produced at the low point blocking the flow of steam.

 Insulate the steam outlet piping if the piping run exceeds 10 feet or 
is exposed to cold areas. Use steam rated insulation.

 Pitch/angle steam lines back towards generator before any up or 
down turns; pitch/angle towards steam room after any up or down 
and avoid perfectly level plumbed lines.

THERMASOL.COM  

I

  800.776.0711

9

Wellness Steam Package

Summary of Contents for ThermaTouch TT7 Series

Page 1: ...Wellness Steam Package OVER 60 YEARS OF STEAM SHOWER INNOVATION Installation Manual For Tutorials and Troubleshooting visit www thermasol com solutions ...

Page 2: ...2 2 ThermaTouch Control 7 Inch Screen Installation Manual For Tutorials and Troubleshooting visit www thermasol com solutions TT7X XX OVER 60 YEARS OF STEAM SHOWER INNOVATION ...

Page 3: ...PPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY IF YOU ARE FEELING UNCOMFORTABLE DIZZY FAINT OR STARTING TO FALL ASLEEP IMMEDIATELY EXIT THE STEAM ROOM DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT THERMASOL STEAM BATH GENERATORS ARE NOT DESIGNED TO BE ...

Page 4: ...ing Power Supply Brick Item 03 7142 Materials needed o ThermaTouch control o M12 cable o Silicone o Power Distribution Module PDM o Mud Ring o Ethernet Cable with RJ 45 Connector not supplied o Other materials as required Back of Control REMINDER in order to receive software updates the unit must be plugged into the internet using an Ethernet Cable connected to a Router Router and Ethernet Cable n...

Page 5: ...er location DO NOT pinch nail staple wedge or bind the data cable DO NOT wrap the data cable around steam line or route it in a manner so that the hot steam line could melt the cable Any damage to the control cable will result in the control not working properly Carefully connect the data cable to the PDM and control BEFORE turning power on to the generator or PDM ON Turn Clockwise OFF Turn Counte...

Page 6: ...ALING THE CONTROL TO THE WALL Power on the control and see that it lights up Coat the entire groove on the control back with supplied waterproof silicone to fully seal the control to the wall Completely seal the control to the wall so moisture does not collect behind it Place the control on the wall pressing firmly You may need to tape the control into place until the silicone dries Be careful not...

Page 7: ...LS 110v 110v M12 Cable Audio Cable M12 Cable M8 Cable M12 Cable 6a Connecting ThermaTouch to Generator 6b Connecting ThermaTouch to Serenity Light Sound Rainhead THERMASOL COM I 800 776 0711 7 Wellness Steam Package ...

Page 8: ...rmaTouch to Digital Shower 6b Connecting Total Wellness Package THERMASOL COM I 800 776 0711 TTC SLS 110v M12 Cable M12 Cable Audio Cable TTC SLS 110v M12 Cable M12 Cable Audio Cable M8 Cable 8 8 Wellness Steam Package ...

Page 9: ...es a 1 2 brass union for easy installation not included Use 1 2 brass pipe or copper tubing from unit to steamhead rough in fitting as permitted by code A B The steam line can run up and then down once or horizontal but never run down and then up If it does a steam trap will be produced at the low point blocking the flow of steam Insulate the steam outlet piping if the piping run exceeds 10 feet o...

Page 10: ...t be sealed to the wall to not allow vapor or water behind it plumbing must be done from backside of finshed space For new framing Mount and install rough in fitting to be flush with finished wall Connect a 1 2 NPT brass pipe or copper tubing to the steam outlet union not included on the generator running the pipe to the steam head location in the wall to connect with the steamhead rough in fittin...

Page 11: ...f applicable 8 Final Pre Check Before Operation Upon final installation mount steamhead with facing up to allow aromatherapy well to dispense steam For detailed installation instructions of the steamhead please see Installation section in thermasol com customer support Apply a small amount of supplied lubricant directly on the o rings Once the shower wall is complete and the housing is sealed to t...

Page 12: ...Serenity Light Sound Rain Head OVER 60 YEARS OF STEAM SHOWER INNOVATION Installation Manual For Tutorials and Troubleshooting visit www thermasol com solutions SLSRRD XX SLSSQ XX 12 12 ...

Page 13: ... BEFORE USE THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS AS THIS CAN BE HAZARDOUS TO YOUR HEALTH YOUR SHOWER MAY BE A SLIP AND FALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM E...

Page 14: ...e Cutter o Ply Wood Backing Board o 36 long 3 8 Compression Flexible Water Line o Separate water volume control diverter with shut off valve Tighten retaining spring to half its normal height Plywood Waterproof Backing Mortar Finished Show er Surface 3 1 2 x 1 4 threaded rod bolt studs Retaining nut Retaining washer Retaining spring Fig 1 Installation Profile View Compatable controls ThermaTouch 7...

Page 15: ... printed out at actual size Install suitable wood support between joists 7 16 Cutout PDM Sold and ships with ThermaTouch control as well as with the other ThermaSol wellness packages ThermaTouch Control sold separately This 25 foot Yellow M12 Cable Item 03 7149 25 ships with ThermaTouch control This 25 foot Yellow M12 Cable Item 03 7149 25 ships with Serenity Light Sound Rain Head 25 foot Audio Ca...

Page 16: ... for the Rain Head The connection to the Rain Head needs to be 3 8 compression Please connect the 36 flex water supply from the water source to the Rain Head Do NOT over tighten Slowly open the water and check for leaks before proceeding Flex Water Supply Connect the Audio cable that is connected to the ThermaTouch control Red to R White to L and make sure that both cables are connected to the sam...

Page 17: ... the three provided screws and secure them into the fixture which will connect with the couplings Tighten them carefully so you don t cross thread them or you don t damage the fixture Allow silicone to dry for 24 hours Make sure that the M12 power data cable is connected from the Rain Head to PDM PDM must be plugged in to standard 110V electrical outlet If your control is plugged in and powered ON...

Page 18: ...18 1 2 3 4 5 6 7 Template must be full scale 1 1 when printed 1 2 3 4 5 5 7 6 Wellness Steam Package ...

Page 19: ...pport Department In addition we ll keep you informed about your product and time to time we ll update you about new products and other company announcements Thank you from all of us at ThermaSol and we wish you many relaxing and steamy days ahead We will not sell rent or share your personal information 1958 Steam Way Round Rock TX 78665 19 THERMASOL COM I 800 776 0711 Wellness Steam Package ...

Page 20: ...1958 STEAM WAY ROUND ROCK TX 78665 PHONE 800 776 0711 FAX 800 556 5257 WWW THERMASOL COM 81240_NC ...