D
D
Remove protective
cap from housing
Insert steamhead
into housing
Use the supplied
silicone to adhere
the steamhead to
the wall
Turn ON the water supply to the generator. Check all the connections for leaks.
Plug in generator (unless hardwired model).
Turn ON the power source or breaker.
Verify control panel lights up and test operation. Note: Initial power-on phase takes several minutes for generator to
heat up steam.
Please direct the home owner to visit www.thermasol.com/solution and click on the “I’m the home owner” button to
learn about set-up and programing (in order to set up the clock and any other options if applicable).
8
Final Pre-Check Before Operation
Upon final installation mount steamhead with
facing up
to allow aromatherapy well to dispense steam.
For detailed installation instructions of the steamhead please
see Installation section in thermasol.com/customer-support
Apply a small amount of
supplied lubricant directly
on the o-rings.
Once the shower wall is complete and the housing
is sealed to the wall, remove the protective cap and
insert the steamhead into housing. Use the supplied
silicone to adherethe steamhead to the wall sealing
out any water from getting behind the head.
Use supplied o-ring lubricant to assist in steam head
installation. A very small amount is all that is need directly
on the o-rings.
Allow 24 hours for silicone to dry before use.
THERMASOL.COM
I
800.776.0711
11
Wellness Steam Package