INTRODUCTION 

These instructions are designed to be read in conjunction with the main product installation manual. Particular attention should be paid to 
all the relevant legislative requirements, including Building Regulations, Water Regulations, IEE Wiring requirements and good practice. 
This installation shall only be conducted by a person competent to do so. 

This pre-plumb unit is a stainless steel unvented indirect hot water storage cylinder with factory built hot water central heating controls 
assembled onto the front outer case of the cylinder

The cylinder may be a single coil indirect for connection to a fossil fuel boiler or a 

twin coil unit for integration with a solar panel system, which in this instance, the pre-plumb controls are assembled onto the upper coil. 

In addition to the components supplied with a standard (non pre-plumb) the following are included:- 

COMPONENT 

SINGLE ZONE KIT 

QUANTITY 

TWIN ZONE KIT 

QUANTITY 

FITTED / 

LOOSE 

PRE-PLUMBED 

& / OR WIRED 

Pipework Manifold 

Fitted 

 

Two Port Motorised Valve 

Fitted 

PCB Wiring Centre 

Fitted 

Dual Cylinder Thermostat 

Fitted 

6m Head Circulator 

Fitted 

Auto By-Pass Valve 

Fitted 

Auto Air Vent 

Fitted 

Sealed System Filling Loop 

Fitted 

Primary Adapter C/W Expansion Valve & Gauge 

Loose 

Primary Expansion Vessel 

(120 - 210 = 12L Exp, 250 = 18L Exp, 300 = 24L Exp)

  

Loose 

System Programmer 

1 x Two Channel 

1 x Three Channel 

Loose 

Room Thermostat 

Loose 

POTABLE WATER CONNECTIONS 

The potable (secondary) water connections are 22mm compression and are connected under the same manner as listed in the main 
installation manual. These connections include; cold mains to inlet control set, equalised cold supply from inlet control set, hot water draw 
off, secondary return connection (where fitted), expansion vessel, vessel bracket and vessel fitting, and tundish disharge pipework. 

PRIMARY WATER CONNECTIONS 

All primary pipework connections are 22mm compression with gland nut and olive at each connection point and require connection in the 

standard method. 

Boiler flow:- 

Remove and discard the transit pipe under the circulating pump by releasing the outer of the pipe clamp and the gland nut to 

the pump isolation valve. Connect the boiler flow pipework directly into the pump isolation valve re-using the pipe clamp to provide 
support to both the pipework and the circulating pump. 

Heating flow:- 

Connect from the 2-port heating valve the heating flow into the radiator circuit. 

Heating Return

:- 

The heating return pipework returns back into the pre-plumb cylinder pipework connecting to the 22mm connection on 

the left hand side of the unit adjacent to the dual cylinder thermostat. 

Boiler Return:- 

The pipework connection from both the central heating and the hot water circuit is the lower left 22mm connection below 

the heating return. This connection requires piping directly back to the boiler. 

Primary Expansion:- 

This pre-plumb unit is supplied c/w a manifold connector facilitating the expansion vessel, expansion discharge 

valve and pressure gauge. The assembly is usually installed in the pipework adjacent to the boiler appliance - see both the boiler 
manufacturers requirements and the instructions provided with the components supplied. Check the vessel is charged to 1.5 bar on 
installation. Ensure the discharge pipe terminates at a point where the discharge of hot water is visible, yet does not cause any danger to 
persons. 

Summary of Contents for Evocyl

Page 1: ...TALLATION MANUAL ISSUE 1 2018 FOR MORE INFORMATION GO TO WWW THERMAQ CO UK IMPORTANT By installing this product you agree to be bound by the terms and conditions supplied within the manual or available for download via our website ...

Page 2: ... manual These connections include cold mains to inlet control set equalised cold supply from inlet control set hot water draw off secondary return connection where fitted expansion vessel vessel bracket and vessel fitting and tundish disharge pipework PRIMARY WATER CONNECTIONS All primary pipework connections are 22mm compression with gland nut and olive at each connection point and require connec...

Page 3: ...ease all air from the auto air valve at the highest point of the pre plumb pipework and also any other high points in the system The normal fill pressure is 1 0 bar to 1 5 bar check both the boiler and radiator manufacturers requirements During filling ensure all plumbing connections including factory made connections are water tight prior to leaving the factory the effects of transit may cause so...

Page 4: ...ff Cold Inlet Secondary Return where fitted Heating Flow Zone 2 Heating Flow Zone 1 Balanced Cold Expansion Vessel Tundish Discharge Heating Return Return To Boiler Flow From Boiler Twin Zone Cylinder Depicted For Illustration Purposes Only ...

Page 5: ...4 SINGLE ZONE WIRING REQUIREMENTS ...

Page 6: ...5 TWIN ZONE WIRING REQUIREMENTS ...

Page 7: ...tat 1 Room Stat 2 ThermaQ SMART Wi Fi Pre Plumbed Wiring Centre Links should be put into the Programmer strip from L to CH1 CH2 to ensure the Room Stat L 1 terminal is always live For any questions or for more information please contact ThermaQ on 01924 270847 SMART Wi Fi Wiring Requirements The following diagram details how to link the wiring centre to the Wi Fi SMART controls L E N L 1 N N 0 L E...

Page 8: ...ThermaQ Limited Sandbeds Trading Estate Dewsbury Road Ossett WF5 9ND Tel 01924 270847 Fax 01924 224283 Web www thermaq co uk ...